IBM IntelliStation 6866 Hardware Maintenance Manual page 56

Table of Contents

Advertisement

Diagnostic Error Code
000-000-XXXBIOS Test Passed
000-002-XXXBIOS Timeout
000-024-XXXBIOS Addressing test failure
000-025-XXXBIOS Checksum Value error
000-026-XXXFLASH data error
000-027-XXXBIOS Configuration/Setup error
000-034-XXXBIOS Buffer Allocation failure
000-035-XXXBIOS Reset Condition detected
000-036-XXXBIOS Register error
000-038-XXXBIOS Extension failure
000-039-XXXBIOS DMI data error
000-195-XXXBIOS Test aborted by user
000-196-XXXBIOS test halt, error threshold exceeded
000-197-XXXBIOS test warning
48
IBM IntelliStation Type 6866: Hardware Maintenance Manual
FRU/Action
1.
No action
1.
Flash the system
2.
System board
1.
Flash the system
2.
System board
1.
Flash the system
2.
Boot block
3.
System board
1.
Flash the system
2.
Boot block
3.
System board
1.
Run Setup
2.
Flash the system
3.
Boot block
4.
System board
1.
Reboot the system
2.
Flash the system
3.
Run memory test
4.
System board
1.
Flash the system
2.
System board
1.
Flash the system
2.
Boot block
3.
System board
1.
Flash the system
2.
Adapter card
3.
System board
1.
Flash the system
2.
System board
1.
Information
2.
Re-start the test, if necessary
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
1.
Make sure the component that is called out is
connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning statement
4.
Component under test

Advertisement