IBM IntelliStation 6866 Hardware Maintenance Manual page 77

Table of Contents

Advertisement

POST Error Code
164 POST detected a base memory or extended memory
size mismatch error or RIMM socket 3 is populated with a
RIMM memory module
166 Boot Block Check Sum Error
167 Microprocessor installed that is not supported by the
current POST/BIOS
168 Alert on LAN error
17X, 18X
175
176
177 Corrupted Administrator Password
178
183
184 No RFID Antenna
185 Corrupted boot sequence
186
187
189
190 Chassis intrusion detector was cleared. This is
information only, no action required. If this code does not
clear, see FRU/Action.
1XX Not listed above
201, 20X Memory data error
225
229 External cache test error
FRU/Action
1.
Run Setup. Check System Summary menu for
memory size change. (See "Setup Utility program"
on page 5)
2.
Run the Extended Memory Diagnostic tests
1.
Run Flash Recovery using Boot Block. See "Flash
recovery boot block jumper" on page 80.
2.
System Board
1.
Run Setup. Check Stepping level for the BIOS level
needed, then perform the flash update.
2.
Processor
1.
Run Setup. Check to see that Ethernet and Alert on
LAN2 are enabled.
2.
System Board
1.
C2 Security
1.
Run Configuration. See "Setup Utility program" on
page 5.
2.
System Board
1.
Covers were removed from the computer
1.
System Board
1.
System Board
1.
Enter the administrator password
Make sure Asset Care and Asset ID are enabled in
Configuration/Setup
2.
RFID Antenna
3.
System Board
1.
Set configuration and reinstall the boot sequence
1.
System Board
1.
Clear Administration password
2.
System Board
1.
More than three password attempts were made to
access the computer
1.
System Board
1.
System Board
1.
Run Enhanced Diagnostics Memory Test
2.
Memory Module
3.
System Board
1.
Unsupported Memory
1.
L2 Cache Memory
2.
System Board
69
Symptom-to-FRU index