Installing vent Components (
Begin the vent system installation by installing the first Simpson Duravent
component, 90° elbow to the starting collars or straight pipe on the top
of the appliance, then the straight pipe length and then horizontal or
vertical termination kit.
NOTE: All outer connection joints must be sealed with aluminum
tape, screws or silicone sealant rated above 300°F/149°C. The inner
flue joints do not require any sealant.
90° ELBOW
OR
45° ELBOW
90° ELBOW
CEILING FIRESTOP
WALL STRAP
PIPE LENGTH
29004-5-1112

vENT SYSTEM IDENTIFICATION

Figure
34)
Figure 34
Simpson Duravent vent system components lock into place by sliding
the concentric pipe section with four (4) equally spaced interior beads
onto the appliance collar or previously installed component end with
four (4) equally spaced indented sections. When the internal beads
of each starting outer pipe line up, rotate pipe section clockwise 90°
(approximately 3 inches). The vent pipe is now locked together.
Continue adding components per the pre-planned vent system
configuration. Be certain that each succeeding vent component is securely
fitted and locked into the preceding component in the vent system.
WALL THIMBLE
HORIZONTAL
TERMINATION
(MAXIMUM OF
TWO 90° ELBOWS)
Special venting components (Simpson Duravent)
See Empire Comfort Systems Retail Price List for Simpson Duravent part
numbers and pricing.
Available from Empire Comfort Systems, Inc. dealers.
Direct-Vent Fireplace Vent Kit - Vertical, Includes SD46DVAF6,
DvvK-4vp
SD46DVASC, and SD46DVAVCH
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 8 to
DvvK-4Tp
11 inch wall thickness, Includes SD46DVA08A, SD46DVA09,
SD46DVAE90, SD46DVAHC, and SD46DVAWT
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 5 to
DvvK-4TSp
7 inch wall thickness, Includes SD46DVA06, SD46DVAE90,
SD46DVAHC, and SD46DVAWT.
Direct-Vent Fireplace Vent Kit for Rear Vent, Thru-the-wall, 5 to
DvvK-4RE
7 inch wall thickness, (standard thru-the-wall venting).
DvvK-4Fv
Vertical Flex Vent Kit 4" x 7"
DvvK-4F
Horizontal Flex Vent Kit 4" x 7"
Direct-Vent Fireplace Flex Vent Extension Kit - Includes 25 ft. f
DvEK-25
4 in. and 7 in. Flex Vent, couplings, and gear clamps. For use
with DVVK-4FV
Direct-Vent Fireplace Flex Vent Extension Kit: Includes 10 ft. of
DvEK-10
4 in. and 7 in. Flex Vent, couplings, and gear clamp. For use
with DVVK-4FV
vIB6A
Vertical Inlet Baffle Kit For 6 5/8" diameter
VERTICAL
TERMINATION
(MAXIMUM OF
THREE
90° ELBOWS)
STORM COLLAR
ROOF FLASHING
Special DV Vent Kits
Page 31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dlcx36sp93p-1Dlcx36sp93p

Table of Contents