Daikin E-Series Service Manual page 384

Hide thumbs Also See for E-Series:
Table of Contents

Advertisement

SiENBE18-621
2.3.2 Duct Connected Type
FDXS25/35CAVMB, FDXS50/60CVMB, FDXS25/35EAVMB
PCB1
PCB2
LED LED LED
S1
S26
1
1
H1P H2P
H3P
S1W
SIGNAL
10
10
RECEIVER
2 RTH1
S32
1
2
BRN
BRN
R1T
R2T
INFRARED
:
REMOTE
C1
:
CONTROL
F1U :
2.3.3 Floor / Ceiling Suspended Dual Type
FLXS25/35/50/60BAVMB
PCB3
S25
S24
LED LED LED
H1P
H2P
H3P
PCB4
S1W
SIGNAL
S27
S26
RECEIVER
S31
S32
R1T
R2T
INFRARED
REMOTE
CONTROL
Appendix
V1TR
(
)
TERMINAL FOR
CENTRALIZED CONTROL
6
S21
S1
RED
S7
1
GRY
1
3
PPL
indoor
BLU
PROTECTIVE EARTH
CAPACITOR ( M1F )
FUSE
PCB1
S37
S36
C70
HA
H4
H5
S7
S21
S6
X21A
M
M
1~
M1S
°C
100
H1
F1U
3.15A
H2
H3
TRANSMISSION
GND
3
1
CIRCUIT
BLK
YLW
H1P ~ H3P
C1
M1F
WHT
PCB1 ~ PCB2
Q1M
M
~
1
Q1M
R1T ~ R2T
130°C
S1 ~ S32, RTH1
M1F
S1W
V1TR
X1M
Z1C
PCB2
H1
Fu
3.15A
BLK
WHT
H2
RED
GRN
H3
TRANSMISSION
CIRCUIT
H6
indoor
X11A
: PROTECTIVE EARTH
C70
: RUNNING CAPACITOR
FU
: FUSE
M1F
H1P~H3P : PILOT LAMP
M1F
: FAN MOTOR
M1S
: SWING MOTOR
Wiring Diagrams
X1M
BLK
1
WHT
2
RED
3
Z1C
GRN
/
YLW
N=2
FIELD WIRING.
GRN
/
YLW
CAUTION
NOTE THAT OPERATION WILL
RESTART AUTOMATICALLY IF
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
ON AGAIN.
: PILOT LAMP
: FAN MOTOR
: PRINTED CIRCUIT BOARD
: THERMAL PROTECTOR ( M1F EMBEDDED )
: THERMISTOR
: CONNECTOR
: OPERATION SWITCH
: PHASE CONTROL CIRCUIT
: TERMINAL BLOCK
: NOISE FILTER ( FERRITE CORE )
X1M
1
2
3
/ YLW
FIELD WIRING.
CAUTION
NOTE THAT OPERATION WILL
RESTART AUTOMATICALLY IF
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
ON AGAIN.
PCB1~PCB4
: PRINTED CIRCUIT BOARD
R1T~R2T
: THERMISTOR
S6~S37, X11A, X21A : CONNECTOR
S1W
: OPERATION SWITCH(SW7)
X1M
: TERMINAL STRIP
1
2
3
outdoor
3D045012K
1
2
3
outdoor
3D033909E
373

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents