Kohler K91 Owner's Manual page 265

4 hp/7 hp/8 hp
Hide thumbs Also See for K91:
Table of Contents

Advertisement

Parts available only through Authorized Dealers.
When ordering parts always list Part
No.
and Description.
ISpecifications subject t o change without
notice.)
ITEM
PART
NO.
NO.
DESCRIPTION
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
5998
909000
5996
920229
920078
933 196
7266
7268
971
1
7267
6444
970
1
971
0
7054
971
0
7264
7052
705
1
7050
70 A9
1
1
1
1
971017
7752
7753
7754
7755
7756
943462
9733 10
7877
Plate Tension
Screw Round Head
#8-32 x
Cam
Washer
Lockwasher # 8
Roll Pin
3/16
x
2
VaIve
Ring
Back Up
"0"
Ring
Assembly Dampening Valve (with
"0"
Rings)
"0"
Ring
"0"
Ring
Assembly Piston
&
Sleeve (Matched Assembly)
" 0 "
Ring
Spring
Relief Valve
Spring
Relief Valve
Seat
Spring
Cone Relief
Valve
Sleeve
"0"
Ring
Plug
Spring
Check
Valve
Valve
Check
Valve
Spring Charge
Pump Relief Valve
Cone Relief
Valve
Plug Pipe Hex Socket 1/2-14
"0"
Ring
Sea
I
Plug
REQ'D.
NO.
2
2
1
2
2
1
1
1
2
1
2
2
2
2
2
2
2
2
2
2
2
7
2
2
1
1
1
7
1
PUMP SHAFT SEAL
REPLACEMENT
Replacement of the
pump shaft
seal (Fig. 91),
i s
accomplished without removing
the Hydrogear as-
sembly from the tractor.
Raise the seat. Remove
the fan guard and fan
on
1965, 1966,
and 1967 models. On 1968 and 1969
models, remove the
belt guard. To do this it will
also
be
necessary to remove the
R.H.
foot rest on
these models.
Loosen the belt ,tension
by setting the parking
brake, and remove the
belt from
the
shaft pulley.
Remove the pulley and Woodruff key from
the input
shaft.
NOTE:
It
is
extremely important not to damage
the shaft or the soft
aluminum housing.
The
follow-
ing steps should
be
done very carefully.
Slide
a small
hook tool or screw
driver along
the
shaft into
the lip seal. Tip the
tool until it
contacts
the outer
metal edge of
the seal and pry outward
gently. Change position of
the tool and repeat the
process until the seal has been
worked out of
the
housing. Discard the
seal.
Inspect 'the shaft and polish out any nicks or burrs
that could
cut or
damage a new
seal. Do
not let
any particles
enter the pump.
Coat the
sealing lip with
automatic transmission
fluid and slide the seal over the
shaft. Align the seal
to the aluminum
housing. A thin
coat of gasket
shellac
on'
the seal O.D.
will aid in
sealing the steel
seal to the pump housing.
Place a tool approximately the size of the seal
O.D. over the metal face of the seal (the
input pulley
hub can be used) and press the seal into the housing
until the seal
is flush with the edge
of the housing.
Check
oil
level and replenish as necessary.
Align and install
the pulley, belt, and fan
if
so
equipped. Install the belt guard or fan guard
de-
pending on
model.
Test operation and
check
for leaks.