Review Section 1
1.
mechanical, pressure
2.
pressure
3.
Hydrostatics
4.
distance
5.
work
6.
gallons, minute
7.
fixed constant
8.
Pressure Control, Direction Of Flow, Volume Of Flow
9.
mechanical energy
10.
single action
Review Section
#
2
1.
Both gauges will read the same amount of pressure because they are in the same circuit.
2.
Circuit A
-
Force is equal to pressure times the area on which it is acting. The pressure is the same in
both circuits. The cylinder in circuit A is larger than the cylinder in circuit The same pressure times a
larger area will generate the most force.
3.
Valve C
-
Valve A is a check valve which keeps oils from returning
to the reservoir during pumping. Valve
B keeps the oil trapped under the lift cylinder. Valve C is used as a pressure relief valve and as a flow
control valve to let the cylinder down.
Review Section 3
1.
D
2.
c
3.
A
4.
easy
5.
load
6.
pressures