Off Mode

The system +5V supply also turns off. However, +5VE (+5V for energy saver
mode) is still activated. When the machine detects a ringing signal, off-hook signal,
or receives a print job, the machine returns to the Off Stand-by mode and the
system +5V and +24V supplies are activated.

Returning to stand-by mode

The machine returns to stand-by mode when the operation switch is pressed. The
recovery time is about 10 s (B291/B296) or 15 s for the (B295/B297).
Operation
Mode
Switch
Off Stand-by
Off
Off
Off
SM
CÓPIA NÃO CONTROLADA
Energy
Saver
Fusing Lamp
Mode
Off
Off
(On when printing)
Off
Off
6-105
CÓPIA NÃO CONTROLADA
ENERGY SAVER MODES
System
+24V
Note
+5V
On
On
+5VE is
Off
Off
supplied
B291/B295/B296/B297