4. 1-Way Air Discharge Semi-concealed Type

4-3. Other component specifications

MODEL NO.
Power Transformer
1
Rated
Primary
Secondary
Coil resistance
Thermal cut off temperature
Thermistor (Coil sensor)
Coil resistance
Thermistor (Room or coil sensor)
Coil resistance
Solenoid control valve or coil
Solenoid control valve
Solenoid coil
Drain pump
Rated
Float switch
Rated (Contact rated)
Indoor Unit
V, Hz
˚ C
KΩ
KΩ
ECO MULTI SYSTEM Unit Specifications
SPW-AS93 · 123GH56
ATR-II215TB
AC 230 V, 50 Hz
10.2 V 1.4 A
14 V 0.5 A
WHT –WHT : 110
RED – RED : 2.3
PBC-41E-S14 , PBC-41E-S25
-10 ˚C : 23.7 ± 5 %
-5 ˚C : 18.8 ± 5 %
0 ˚C : 15.0 ± 5 %
5 ˚C : 12.1 ± 5 %
10 ˚C : 9.7 ± 5 %
KTEC-35-S6
0 ˚C : 16.5 ± 5 %
5 ˚C : 12.8 ± 5 %
10 ˚C : 10.0 ± 5 %
20 ˚C : 6.3 ± 5 %
30 ˚C : 4.0 ± 5 %
LAM-B30YHST1
LAM-MDI2ST-1
WP20SL-14
AC 230 V, 14.7 W
FS-0218-102
AC 230 V, 50 W
I - 52
,
BRN – BRN : 0.5
145
20 ˚C : 6.5 ± 5 %
,
30 ˚C : 4.4 ± 5 %
,
40 ˚C : 3.1 ± 5 %
,
45 ˚C : 2.6 ± 5 %
,
40 ˚C : 2.7 ± 5 %
,
45 ˚C : 2.2 ± 5 %
,
50 ˚C : 1.8 ± 5 %
,
55 ˚C : 1.5 ± 5 %
,
SM830052