Room Temperature Control - Sanyo SPW-C483GYH8 Service Manual

Eco multi system
Table of Contents

Advertisement

7. Room Temperature Control

The thermostat is switched on/off by ∆T as follows.
∆T = (Room temperature) – (Set temperature)
Remote control thermostat
Body thermostat
* Shift temperature (valid only for heating)
0 ˚C ~ 10 ˚C can be selected with the remote controller simple setting mode.
(Factory settings: floor standing type ----- 0 deg; wall-mounted type ----- 2 deg; other types ----- 4 deg)
: THERMO. ON
T
+1.0
0
-1.0
Cooling
Supplement:
(1) After thermo.-on, it will not thermo.-off for 3 minutes due to ∆T .
However, for heating, if the indoor coil E2 temperature ] 64 ˚C, it will thermo.-off within 5 minutes (over load
protection).
(2) After thermo.-off, it will not thermo.-on for 1 minute.
For cooling or dehumidifying, it will not thermo.-on if the indoor coil E1 or E2 temperature < 6 ˚C.
(3) At the start of operation, the slope is down (thermo.-on).
(4) When the system is set for test operation, it will not thermo.-off for 60 minutes (forced thermo.-on).
Room temperature = remote control sensor
Room temperature = (Body sensor) – (Shift temperature*)
II - 7
: THERMO. OFF
T
+1.0
0
-1.0
Heating
Processes and Functions
0319_M_I
SM830052
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents