Other Component Specifications - Sanyo SAP-KM97GHS5A Technical & Service Manual

Multi-split system air conditioner
Table of Contents

Advertisement

2-3. Other Component Specifications

Indoor Unit
Transformer (TR)
Rating
Coil resistance
Thermal cut-off temp.
Thermistor (Coil sensor TH1)
Resistance
Thermistor (Room sensor TH2)
Resistance
Outdoor Unit
Power Relay (PRA, PRB)
Coil rating
Coil resistance
Contact rating
Termistor (Coil sensor)
Resistance
Solenoid Coil (4-way Valve SCA, SCB)
Coil rating
Coil resistance
SAP – KM97GHS5A
Primary
Secondary
Capacity
Ω (at 21°C)
kΩ
kΩ
SAP – MC1827GH5
Ω (at 20°C)
kΩ
Ω (at 20°C)
SAP – KM97GHS5A / E
Primary (WHT – WHT):
Secondary (BRN – BRN):
–20°C 40.1 ± 5%
–10°C 24.4 ± 5%
0°C 15.3 ± 5%
10°C
–10°C 23.7 ± 5%
0°C 15.0 ± 5%
10°C
20°C
CHV-01Ai038A1 (Coil), CHV-0101 (Valve)
6
ATR-J125
AC 230V, 50Hz
19V, 0.631A
12VA
205 ± 10%
1.5 ± 10%
150°C
PBC-41E-S4
20°C 6.5 ± 5%
30°C 4.4 ± 5%
40°C 3.0 ± 5%
9.9 ± 5%
50°C 2.1 ± 5%
DTN-TKS106E
25°C
5.0 ± 3%
DFU24D1-F (M)
DC 24V
650 ± 10%
AC 250V, 20A
PBC-41E-S15
25°C 5.3 ± 5%
30°C 4.4 ± 5%
9.7 ± 5%
40°C 3.1 ± 5%
6.5 ± 5%
AC 230V, 50Hz, 5W
1,408 ± 7%