Sanyo SPW-C483GYH8 Service Manual page 65

Eco multi system
Table of Contents

Advertisement

5. Wall Mounted Type
5-2. Major component specifications
Indoor unit (A)
MODEL No.
Source
Controller P.C.B. Ass'y
Fan (Number...diameter)
Fan motor
Model...Nominal output
Source
No. of pole...r.p.m. (230 V, High)
Coil resistance
(Ambient temperature 20 °C)
Safety device
Operating temperature
Run capacitor
Electronic refrigerating control valve
Elec. magnetic coil model
Coil resistance (at 20 °C)
Solenoid control valve model
Heat exchanger
Coil
Rows...fin pitch
Face area
Auto louver motor
Rated
No. of pole...r.p.m.
Nominal output
Coil resistance (at 25 °C)
ECO MULTI SYSTEM Unit Specifications
220 - 230 - 240 V / 1 phase / 50Hz
mm
W
220 - 230 - 240 V / 1 phase / 50 Hz
rpm.
BRN – WHT : 208.5
WHT – VLT
VLT – ORG : 17.59
Open °C
Close °C
VAC, µF
ORG – RED : 48 ,
RED – WHT : 48 ,
Aluminum plate fin / Copper tube
mm
m
2
rpm.
W
I - 59
SPW-K93GH56
CR-X253GH (Microprocessor)
Cross-flow (1 ... ø 81 / L 610)
UF2Q-21C5P ... 20 W
2 ... 1,160
ORG – YEL
: 84.20
YEL – PNK
130 ± 5 °C
Differential 15 deg. (min.)
440 V, 0.8 µF
LAM-MD12ST-1
YEL – BRN : 48
BRN – BLU : 48
LAM-B30YHST1
2 ... 1.7
0.172
M2LJ24ZE31
AC 230 V-50 Hz
8P – 2.5
3
16,450 Ω ± 15 %
1
: 72.32
: 44.89
SM830052

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents