Main Operating Functions; Remote Control Functions; Room Temperature Control - Sanyo CHDZ07263 Service Manual

Hide thumbs Also See for CHDZ07263:
Table of Contents

Advertisement

1. Main Operating Functions

1-1. Room Temperature Control

The thermostat is turned ON/OFF according to
When remote controller sensor
is used
When body sensor is used
* Intake shift temperature (enabled only during heating)
During heating, a difference in temperature occurs between the top and bottom of a room. This value is set in consideration for
the difference between the temperature detected by the body sensor and the temperature at the bottom of the room.
<Value set for intake shift temperature at time of shipment>: 7°F
NOTE
The shift temperature can be selected in the range of 0 – 18°F, by using the remote controller simplifi ed setting mode.
Room temperature
(deg)
1
Set temperature
Thermostat
2
(1) After the thermostat turns ON, it will not turn OFF again as a result of
(2) After the thermostat turns OFF, it will not turn ON again for 3 minutes. (It also will not turn ON for 3 minutes after the power
is switched ON.)
3
(3) The compressor turns OFF if the mode is changed cooling
(4) If "test run" mode is selected, the thermostat will not turn OFF as a result of
ON.)
4
5
6
7
T = Room temperature - Set temperature
Room temperature = Temperature detected by the remote controller sensor
Room temperature = Temperature detected by the body sensor - Intake shift temperature*
Cooling
T
+4
+2
–2
ON
OFF
T as shown below.
Room temperature
Set temperature
ON
Thermostat
T for 5 minutes.
heating (or heating
2 - 2

Remote Control Functions

Heating
T
(deg)
+2
–2
–4
ON
OFF
cooling) while the compressor is ON.
T for 60 minutes. (The thermostat is forced
ON