User Constants

Factory settings are given in the following table.
No.
Language selection for Digital
A1-00
Operator display
A1-01
Constant access level
A1-02
Control method selection
A1-03
Initialize
A1-04
Password
A1-05
Password setting
A2-01 to
User setting constants
A2-32
b1-01
Reference selection
b1-02
Operation method selection
b1-03
Stopping method selection
b1-04
Prohibition of reverse operation
Operation selection for setting E1-
b1-05
09 or less
b1-06
Read sequence input twice
Operation selection after switching
b1-07
to remote mode
Run Command selection in pro-
b1-08
gramming modes
b1-10
Mode selection for zero-speed
Zero-speed level (DC injection
b2-01
braking starting frequency)
b2-02
DC injection braking current
b2-03
DC injection braking time at start
b2-04
DC injection braking time at stop
Magnetic flux compensation vol-
b2-08
ume
b3-01
Speed search selection
b3-02
Speed search operating current
b3-03
Speed search deceleration time
b3-05
Speed search wait time
Speed search detection compensa-
b3-10
tion gain (speed calculation)
Proportional gain of the speed esti-
b3-13
mator during speed search
b3-14
Rotation direction search selection
b4-01
Timer function ON-delay time
b4-02
Timer function OFF-delay time
b5-01
PID control method selection
b5-02
Proportional gain (P)
b5-03
Integral (I) time
b5-04
Integral (I) limit
b5-05
Derivative (D) time
b5-06
PID limit
b5-07
PID offset adjustment
-20
10
Table 10.2 User Constants
Fac-
Name
tory
Setting
*1
1
2
*1
2
0
0
0
-
1
1
0
0
0
1
0
0
0
0.5
50
0.00
0.50
0
*2
2
*2
100
2.0
0.2
1.10
1.0
1
0.0
0.0
0
1.00
1.0
100.0
0.00
100.0
0.0
Set-
No.
ting
b5-08
PID primary delay time constant
PID output characteristics selec-
b5-09
tion
b5-10
PID output gain
b5-11
PID reverse output selection
Selection of PID feedback com-
b5-12
mand loss detection
PID feedback command loss detec-
b5-13
tion level
PID feedback command loss detec-
b5-14
tion time
b5-15
PID sleep function operation level
b5-16
PID sleep operation delay time
b5-17
Accel/decel time for PID reference
b6-01
Dwell frequency at start
b6-02
Dwell time at start
b6-03
Dwell frequency at stop
b6-04
Dwell time at stop
b7-01
Droop control gain
b7-02
Droop control delay time
b8-01
Energy-saving mode selection
b8-02
Energy-saving gain
b8-03
Energy-saving filter time constant
b8-04
Energy-saving coefficient
Power detection filter time con-
b8-05
stant
b8-06
Search operation voltage limiter
b9-01
Zero-servo gain
b9-02
Zero-servo completion width
C1-01
Acceleration time 1
C1-02
Deceleration time 1
C1-03
Acceleration time 2
C1-04
Deceleration time 2
C1-05
Acceleration time 3
C1-06
Deceleration time 3
C1-07
Acceleration time 4
C1-08
Deceleration time 4
C1-09
Emergency stop time
C1-10
Accel/decel time setting unit
Accel/decel time switching fre-
C1-11
quency
S-curve characteristic time at
C2-01
acceleration start
S-curve characteristic time at
C2-02
acceleration end
Fac-
Name
tory
Setting
0.00
0
1.0
0
0
0
1.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.05
0
*3
0.7
*4
0.50
288.20
*5 *15
20
0
5
10
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
1
0.0
0.20
0.20
Set-
ting