Feed Forward Control Structure
The following block diagram shows the speed controller (ASR) and the feed forward control structure.
Frequency
reference
Setting Precautions
When N5-02 (Motor acceleration time) is not properly set, the acceleration time may not increase. The fac-
tory setting of N5-02 depends on the Inverter capacity. When the Inverter capacity is different from the
motor capacity, calculate an appropriate acceleration time using the equation given in N5-02 of Chapter
User Constants Chapter User Constants or set the time that corresponds to the motor capacity referring to
Factory Settings that Change with the Control Method (A1-02) (Page 5-86)
When setting the feed forward proportional gain (N5-03), take the inertia of the motor to be equivalent to
1. If the speed reference response is slow, increase the feed forward proportional gain (N5-03). If over-
shoot occurs with the actual speed, or if a negative torque reference is output when acceleration is com-
pleted, reduce the feed forward proportional gain (N5-03).
When using the droop control function (i.e., if b7-01 is not set to 0.0), disable feed forward control (i.e., set
N5-01 to 0).

Droop Control Function

Droop control is a function that allows the user to set the amount of motor slip.
When a single load is operated with two motors (such as in a crane conveyor), a high-resistance motor is nor-
mally used. This is to use torque characteristics that exhibit proportion movements due to changes in the sec-
ondary resistor to maintain torque balance with the load and overall speed balance with the load.
If droop control is used, a high-resistance motor characteristics can be set for a general-purpose motor.
Torque
Motor B's torque
characteristics
Load balance when using a general-purpose motor
-138
6
N5-02, N5-03
Feed
forward
controller
Speed controller (ASR)
U1-05
Detected speed
(Calculated speed)
Fig 6.74 Structure of Speed Controller (ASR) and Feed Forward Control
The balance of the load is very different with different amounts of slip.
Motor A's torque
characteristics
T A
Load torque
T B
The difference between
T
and T
is getting larger.
A
B
Reference
Speed
speed
U1-45
Torque limit
U1-44
Primary
filter
C5-06
L7-01 to L7-04
(C5-10)
Motor A's torque characteristics
Torque
Motor B's torque characteristics
T A
T B
Reference
speed
Load balance when using a high-purpose motor
Secondary
current
reference
Load torque
The difference between
T
and T
is getting smaller.
A
B
Speed