Yamaha XVS650 Service Manual page 283

Motorcycle
Hide thumbs Also See for XVS650:
Table of Contents

Advertisement

ELECTRIC STARTING SYSTEM
I
ELEC
I
0
I
eB803021
*
3.Starter motor
A
WARNING
• Connect the battery positive terminal
CD
and starter motor cable
®
using a
jumper lead
®*.
• Check the operation of the starter motor.
• A wire that is used as a jumper lead must
have the equivalent capacity or more as
that of the battery lead, otherwise the
jumper lead may burn.
• This check is likely to produce sparks, so
be sure that no flammable gas or fluid is
in the vicinity.
DOES NOT MOVE
I
Repair or replace the starter motor.
~
MOVES
EB803023
14.
Relay unit (starting circuit cut-off relay)
• Remove the relay unit from the wire har-
ness.
• Connect the pocket tester (0 x 1) and
battery (12 V) to the relay unit terminals.
Battery
(+)
terminal
~
Red/Black terminal
CD
Battery (-) terminal
~
BlacklYellow terminal
®
Tester
(+)
lead
~
Blue terminal
®
Tester (-) lead
~
Blue/White terminal @
• Check the starting circuit cut-off relay for
continuity.
~
CONTINUITY
*
NO CONTINUITY
I
Replace the relay unit.
7 - 14

Advertisement

Table of Contents
loading