(e) CCU-550/550P

Front Panel
Camera number sheet/tally indicator
1
POWER
CAM
MAIN
NCOM
MIC ON
OFF
1) Camera number sheet/tally indicator
Lights red when the red tally signal is input (e.g. when the video
signal from the camera connected to the CCU-550/550P goes on air).
When the CALL button on the camera, an MSU-700, RCP-700 Series
Remote Control panel or an optional BKP-5973 (CCU-550/550P Front
Panel) is pressed, the lamp is illuminated if it was not lit, or is turned
off if it was already illuminated. The indicator illuminates green when
the green tally signal is input (e.g. when the video signal from the
camera connected to the CCU-550/550P goes off air). Attach the
supplied number sheet here to indicate the camera number.
2) POWER switch/CAM (camera) and MAIN indicators
This POWER switch turns the power supply on and off to the entire
camera system, including the CCU-550/550P, the camera and the
remote control unit connected to the REMOTE connector of the
CCU. The MAIN and CAM indicators illuminate when the POWER
switch is turned on. The CAM indicator goes out when the power is
turned off by the CAM PW button on the remote control panel or the
master set-up unit, or by the CAM POWER switch on the internal AT
board.
3) CABLE ALARM indicators
OPEN: illuminates when a triax cable is not connected to the
CAMERA connector on the rear panel of the CCU-
550/550P, or when the load current is extremely low
even when a camera cable is connected.
SHORT: illuminates when there is excessive current flow in the
triax cable.
4) INCOM (intercom) input/output/setting section
INCOM (intercom) connector (XLR 5-pin): Headset connector for a
headset. When you wish to use with a plug other than an XLR 5-pin
type, consult an authorized Sony representative.
POWER switch/CAM and MAIN indicators
2
CABLE
ALARM
OPEN
SHORT
-
PROD
PREV
PGM
PGM
INCOM input/output/setting section
4
Location and Function of Parts and Controls
3
CABLE ALARM indicators
INCOM level control: Adjusts the input level of the intercom.
MIC/PGM (program audio) switch:
ON: The headset microphone is switched on.
OFF: The headset microphone is switched off.
PGM: Program audio is output. When this position is
selected, the INCOM level control adjusts the output
level of the program audio.
INCOM selector: Selects the routing of intercom signals
output/input through the
INCOM/TALLY/PGM connector.
PROD: Selects the producer line.
PRIV: The producer line and engineer line are disabled and
communication is restricted to that between the CCU-
550/550P and the camera connected to its rear panel.
ENG: Selects the engineer line.
10