(D) Ccu-700A/700Ap - Sony BVP-900 Series Product Information Manual

Studio/ob/efp camera family
Hide thumbs Also See for BVP-900 Series:
Table of Contents

Advertisement

10
Location and Function of Parts and Controls

(d) CCU-700A/700AP

Front Panel
2
Green tally lamp
1
Red tally lamp
8
CABLE ALARM indicator
7
MAIN POWER switch and
indicator
1) Red tally lamp
This lamp is illuminated when the unit receives a red tally signal.
When the CALL button on the camera, MSU-700 Master Set-up Unit,
or RCP-700 Series Remote Control Panel is pressed, the lamp is
illuminated if it was not lit, or is turned off if it was already
illuminated. Attach one of the supplied number plates here. For
details on attaching a number plate, refer to the system manual.
2) Green tally lamp
Lights when the unit receives a green tally signal. Attach one of the
supplied number plates here. For details on attaching a number
plate, refer to the system manual.
3) MIC (microphone select) switch
Set to the appropriate position according to the type of headset
microphone.
DYNAMIC: When using a dynamic microphone.
OFF: Switches the microphone off.
CARBON: When using a carbon microphone.
4) INTERCOM (intercom volume) control
Adjusts the receiving level of the intercom. The volume of the sound
mixed with program audio is set with the control on the AT board.
For details on setting mixed-sound volume, refer to the system
manual.
The intercom line can be switched with the corresponding switch on
the internal AT board. For details, refer to the system manual.
5) INTERCOM connector (XLR 5-pin)
Connector for a headset. When you wish to use a headset with a plug
other than XLR 5-pin type, consult an authorized Sony representative.
6) CAMERA POWER switch and indicator
This switch controls the power supply to the camera when the MAIN
POWER switch is set to the ON position (| position). The indicator
illuminates when power is supplied to the camera. If an RCP-700
Series Remote Control Panel or MSU-700 Master Set-up Unit is
connected to this unit, the CAM PW switch on the RCP or MSU
panel must be illuminated to enable this switch to control the camera
power supply.
71
3
MIC switch
4
INTERCOM control
CABLE
MIC
ALARM
CAMERA
MAIN
POWER
POWER
INTERCOM
5
INTERCOM connector
6
CAMERA POWER switch and indicator
CANERA CONTROL UNIT
7) MAIN POWER switch and indicator
This switches the power supply on and off to the entire camera
system including this unit, the camera and an RCP-700 Series
Remote Control Panel connected to the REMOTE connector. The
indicator illuminates when power is supplied to the system. Power is
not supplied to an MSU-700 Master Set-up Unit.
8) CABLE ALARM indicator
SHORT: Illuminated when there is excessive current in the
triax cable or when there is a short-circuit in the unit.
OPEN: Illuminated when a triax cable is not connected to the
CAMERA connector on the rear panel, or when the load
current is extremely low even if a camera cable is
connected.