I
NSTALLATION
P
20
AGE
8 Attach the two male quick-connects from the switch plate to the two female quick-connects leading
from the fireplace. If the optional summer fan switch is being used, connect the other two quick
connects, otherwise tuck the two male quick-connects leading from the fireplace into the cavity
behind the faceplate. Attach the switch plate to the faceplate using a standard screwdriver (NOTE:
the attachment screws are threaded into the faceplate).
+ Blower operation may be checked by jumping the two male quick-connects leading from the
fireplace (BE CAREFUL - THIS CIRCUIT IS ACTIVE). Make sure the door is closed.
Lower Right
of Faceplate
These male quick-connects are for the summer fan switch
(connect them together to test if the blower operates).
9
Test the blower circuit by following the directions below..
( C
ONTINUED
Remove the right
a
forward side brick.
)
Attach the two male quick-connects from the
switch plate to the two female quick-
connects leading from the fireplace.
b
c
Depress the
door switch.
Use a standard
screwdriver to attach
the switch plate
Use a propane torch or
other heat source to heat
the area at the center of
this plate. The blower, if
connected properly,
should start within 30 to 60
seconds.