Blower Electrical Connection - FireplaceXtrordinair 36 ELITE-ZC Installation Manual

Zero clearance fireplace
Table of Contents

Advertisement

I
NSTALLATION
P
12
AGE
Blower Duct Connection (continued)
The maximum length for 8" diameter blower
duct is 25' (use two 6" to 8" adapters)
A maximum of two 90° bends may be used.
The blower, if located on an external wall,
must be weatherproofed. Remove the
blower cover and install the blower. Apply
caulk around the perimeter of the blower
housing where it contacts the external wall
and vapor barrier (apply sparingly). Replace
the blower cover.

Blower Electrical Connection

Connect the electrical
conduit to a 120 Volt, 60
Hz (2 Amp) electrical
supply. Use a junction
box to protect the
electrical connection.
Connect the blower
conduit to the blower
box by attaching the two
molex connectors
together. Insert the
molex connectors into
the blower box. Then
attach the conduit to the
blower box by inserting
it into the top until it
snaps in place.
!
Do not run either conduit over the top of the fireplace or within 2" of the chimney
If the blower or power supply is located to the left, the electrical conduit(s) may be directed to the
left side of the fireplace. To do this, remove the conduit cover plate on both sides of the fireplace.
Feed the conduit(s) through the hole on the right side and out the left side (removing the cover
allows the conduit to be fed through without kinking). Switch the cover plates by attaching the right
cover plate to the left side and vice-versa.
The blower utilizes a filter that requires periodic cleaning - see the illustration below.
( C
ONTINUED
Power
Conduit
Blower
Filter Screen
Housing
)
Caulk around all
four sides of the
blower housing
External Wall (&
vapor barrier)
Snap this piece
into the top of the
Blower
blower housing
Conduit
Black (Hot)
Exposed (Ground)
Screw this piece into
Use wire nuts or other approved method to connect the power
the junction box
conduit wires to a power source (a junction box is required).
Filter
Intake Grill
Shake the filter to remove any
dirt that may have accumulated.
Blower
Cover
Blower
Housing
White (Common)
Remove the four
screws that go into
these holes.
Blower
Housing
Junction
Box