Connecting Relay Modules - Honeywell Ademco Vista-12D Installation And Setup Manual

Table of Contents

Advertisement

Installation and Setup Guide

Connecting Relay Modules

1. Mount either remotely or in the control panel.
2. Connect to control's keypad terminals using the
connector harness supplied with the module.
Use standard 4-conductor twisted cable for long
wiring runs.
3. Set the module's device address according to
the table at right.
4. Connect the desired field wiring to the unit's
relay contact terminals.
Notes
• Use 4204/4229 modules or 6164 keypad.
• Supervision: 4204/4229 modules and 6164
keypad are supervised against removal. The
module's device address is displayed as
follows if a module is disconnected from the
control's terminals, or if the module cover is
removed and the tamper jumper is installed:
2-14
Alpha:
CHECK xx Wire Expansion
FAULT xx Wire Expansion
TAMPER xx Wire Expansion
ALARM xx Wire Expansion
Fixed-Glass: lxx (or 91 if field *199 set for 2-digit
display)
where "xx is the module's address.
• If communication/tamper failure occurs on a
device with zones wired to it, all zones on the
device will be displayed in their respective
partitions.
Relay Module Addresses
4204/6164
Address 4229/6164
2
13
† Use these addresses if using only relays with
the 6164 and not its zones.
†† Use these addresses if using zone expansion
and relays with the 6164; supports only the
first four zones in parenthesis.
NOTE: You can not use a 4229 and 6164 in the
same system.
††† Not available if zone doubling used.
††
Address
(zn 17-24)
08

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents