Loading Factory Defaults/Initializing for Download
To Load Default Entries
To Initialize Download ID
Do not press
previously—data already programmed into the system will be changed!
4
Exiting the Programming Mode
Prevent installer code reentry
Allow installer code reentry
Table of Device Addresses
This Device
RF Receiver
Alternative Communication
Media (ACM)
Telecommand Voice Module
Zone Expanders** (4219/4229):
zones 17 - 24
Keypads:
keypad 1
keypad 2
keypad 3
keypad 4
keypad 5
keypad 6
keypad 7
keypad 8
5800TM Module
† ACM devices include: 7845i Ethernet Interface Internet/Intranet, AI4164RS/AI4164ETH RS485/Ethernet
Eureka Network Interface
†† Addressable devices are identified by "1" plus the device address when reporting. Enter a report code for
zone 91 to enable addressable device reporting (default = reports enabled). See field *199 for addressable
device (ECP) 3-digit/2-digit identification keypad display options
** or 6164 Keypad using zones; 08 = zones 17-20
Press ∗97 while in Program Mode. This resets all data fields to
the default values shown on the Program Form. Use ∗ 97 only if
you wish to return to the original factory-programmed defaults.
Press ∗96 while in Program Mode. This initializes the system for
downloading and resets all the subscriber account numbers and
CSID.
97 to load defaults if any programming has been done
Press ∗98. Exits Programming Mode and prevents re-entry by:
Installer Code + [8] + [0] + [0]. To enter the programming mode if
∗ 98 was used to exit, you must first power the system down.
Then power up again, and press [∗] and [#] at the same time,
within 50 seconds of powering up.
Press ∗99. Exits Programming Mode and allows re-entry by:
Installer Code + [ 8] + [0] + [0] or by: Pressing [∗] and [#] at the
same time, within 50 seconds of power-up.
Uses Address Reports as
00
100
03
103
17-23
117-123
08
108
16
116
17
117
18
118
19
119
20
120
21
121
22
122
23
123
28
n/a
Mounting and Wiring the Control
††
Enabled By...
*56 zone programming: input device type entry
automatic if output to ACM field *29 enabled
same as keypad enables; see below
*56 zone programming: input device type entry, then:
automatic if zone no. 17-24 entered as AW type or
relay assigned
data field programming as listed below:
always enabled for partition 1, all sounds enabled.
data field *190
data field *191
data field *192
data field *193
data field *194
data field *195
data field *196
automatic
.
3-9