Honeywell Ademco Vista-12D Installation And Setup Manual page 77

Table of Contents

Advertisement

PROMPT
Key "A" Func
Zone 95
00
VALID ENTRIES
Define Key Function
00-10 = see list to right
[∗] to continue
Returns to key number prompt
with the next function key letter
displayed.
† System defaults to these
function key settings.
For Options 09 and 10, note that
there are only two macros per
system. Therefore, be careful
when assigning these macros to
the various partitions.
Menu Mode Programming
EXPLANATION
Enter the desired function for this key, 00 to 12,
from the options listed. (00 selected for example
display shown at left)
00
= For the Function key selected, the function
will be as follows:
If A selected = Zone 95 (emergency key,
same as [1] [∗] pair)
If B selected = Zone 99 (emergency key,
same as [∗] [#] pair)
If C selected = Zone 96 (emergency key,
same as [3] [#] pair)
If D selected = Single-button paging
01 =
Single-button paging (sends a 999-9999
message to pager)
02 =
Display time
03 =
Arm AWAY (reports as User 00 if closing
reports are enabled)
04 =
Arm STAY (reports as User 00 if closing
reports are enabled)
05 =
Arm NIGHT-STAY (reports as User 00 if closing
reports enabled)
06 =
Step Arming (arms STAY, then NIGHT-
STAY, then AWAY)
07 =
Output Device Command (for device
programmed as system operation type 66–
function key in *80 Menu Mode)
08 =
Communication Test (sends Contact ID code
601)
09 =
Macro Key 1 (define macro by user code +
[#] [6] [6] command)
10 =
Macro Key 2 (define macro by user code + [#]
[6] [6] command)
5-21