Programming Installer And User Schedules - Honeywell Ademco Vista-12D Installation And Setup Manual

Table of Contents

Advertisement

Installation and Setup Guide

Programming Installer and User Schedules

The system provides up to 8 schedules, which can be used to control 12 types of system events
at pre-defined times. 4 schedules are intended for use by the end-user, and 4 are reserved for
the installer. In addition, some events are also reserved for the installer only (listed in the
"Enter Event" prompt paragraph below).
Start Scheduling mode by entering installer code + [#] + [6] [4] while in normal operating
mode.
NOTE: The master code can only access schedules 01-04 and events 00-08.
The following prompts are displayed:
PROMPT
E N T E R S C H E D N O .
0 0 = Q U I T
0 0
E N T E R E V E N T
NOTE: Events 07 and 10
cause the keypad to
beep every 30 seconds
when messages are
displayed. Stop the
beeps by user code +
OFF.
D E V I C E N U M B E R
X X
G R O U P N U M B E R
X
5-26
VALID ENTRIES
Schedule Number
01-04 = end-user schedules
05-08 = installer-only schedules
[∗] to continue
Enter Event
00 = clear event
01 = Relay On/Off
02 = User Access
03 = Child Not Home Report to
Pager
04 = Forced Stay Arming
05 = Forced Away Arming
06 = Auto Disarm
07 = Display "Reminder"
08 = Disarm Time Window
11 = Periodic Test Report
12 = Up and About
[∗] to continue
Device Number
01-04 = device number
[∗] to continue
Group Number
1-8 = group number
[∗] to continue
EXPLANATION
Enter the desired schedule number.
Enter the desired event number for event you
want to occur at a specified time.
Events 10-12 are reserved for the installer only.
Child-Not-Home report (option 03) is sent to all
pagers in the user's partition (message sent is 777-
7777). User must be enabled for paging (see User
Attributes in System Operation section).
Disarm Time Window (08): System can be
disarmed only during this time period. Exception:
If a burglary alarm occurs, the system can be
disarmed outside the scheduled time window.
† Forced bypass is automatically enabled
regardless of setting in field *23.
This prompt appears if event "1" (relay on/off) was
selected, otherwise it is skipped.
Enter the physical device number as programmed
in ∗79 Menu Mode, then press [*] to continue to
the "Start" prompt.
Device numbers 17 and 18 designate built-in
triggers 1 and 2 respectively.
This prompt appears if event "2" (user access) was
selected. Otherwise it is skipped.
Press [*] to continue to the "Start" prompt.

Hide quick links:

Advertisement

Table of Contents
loading