FUTABA 4PK-2.4G SuperR Instruction Manual page 118

Hide thumbs Also See for 4PK-2.4G SuperR:
Table of Contents

Advertisement

System function setup:MC960CR
1
(Setting item selection)
When the (JOG) button is operated at the bottom side from
the MC960CR data read screen Page1 of the setup screen
is displayed.
Operate the following (JOG) button and switch between
Page1 and Page2 of the setup screen.
Page2
When "LAU" (LEAD ANGLE USE) displayed on Page2 is
turned on the BOOST ANGLE settings are displayed on
Page3. Page1
above except that Page3 is increased.
"LAU" (LEAD ANGLE USE) turned on
Writing of data to the MC960CR is returned from any Page
to the initial read screen and "Writing to ESC" (p.115) is exe-
cuted by operating the (JOG) button up and down2Select the
setting item by (JOG) button up, down, left, or right operation.
Set the value by (+) and (-) button.
Setup item
MIn-(PWM FREC MIN LD) 0.5kHz(500Hz )~ 30kHz(30000Hz)
Same as Link software PWM frequency (at Min. load),
MIn sets the "0"A PWM frequency at minimum load.
MAX-(PWM FREC MAX LD) 0.5kHz(500Hz )~ 30kHz(30000Hz)
Same as Link software PWM frequency (at Max. load).
MAX sets the PWM frequency at maximum load at the output
current limit value set by Current Limiter.
BRK-(PWM FREC BRK LD) 0.5kHz(500Hz )~ 30kHz(30000Hz)
Same as Link software Brake PWM at frequency.
This setting can set the brake PWM frequency.
CLM-(CURRENT LIMIT) 50A~500A , OFF
Same as Link software Current Limiter.
Current Limiter sets the current value at maximum load here.
Since setting of the MAX is based on the output current limit value set by Current Limiter, Current Limiter does not
have to be turned OFF except when a current exceeding 300A is generated.
118
Page1
2
3 transition is the same as Page1
ESC Link Function "MCLNK"
MC960CR data read screen
Page2
2
•Select the setting item by
ton
* blinks at the current setup item.
- The currently set item is dis-
played here.
Page3
Page1
Page1
but-
Page1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents