Clearance To Combustibles; Mantels; Hearth - Majestic 360DVS2 Installation Instructions & Homeowner's Manual

360 dvs series direct vent fireplaces
Table of Contents

Advertisement

360 DVS Series Direct Vent Fireplaces

Clearance to Combustibles

Appliance
Top ......................................... 0" (0mm) to standoff
Bottom ..................................................... 0" (0mm)
Vent End ....................... 1/2" (13mm) to rear panel
Nonvent End (DVS2) ............................... 0" (0mm)
Venting
Concentric sections of DV Vent:
Top, bottom & sides ............................... 1" (25mm)
Nonconcentric sections of DV Vent:
Side and bottom .................................... 1" (25mm)
Top ......................................................... 2" (51mm)

Mantels

The height at which a combustible mantel is fitted
above the fireplace is dependent on the depth of the
mantel. This also applies to the distance between the
mantel leg (if so fitted) and the fireplace. For correct
mounting height and width, refer to Fig. 4a and 4b and
the Mantel Chart below.
The fitting of a bay window trim kit does not affect the
distances and reference points referred to in the
diagram and chart.
Noncombustible mantels and legs may be installed at
any height and width around the appliance.
When using paint or lacquer to finish the mantel, such
paint or lacquer must be heat resistant to prevent
discoloration.
A
B
C
D
Bottom of Door Trim
Mantel Chart
Mantel Shelf
Ref.
or Breast Plate
V
10" (254mm)
W
8" (203mm)
X
6" (152mm)
Y
4" (102mm)
Z
2" (51mm)
Fig. 4a Combustible mantel minimum installation.
8
V
W
X
Y
Z
E
Fireplace
Louvre Assembly
Top
Top of Combustion
Chamber
CFM146
Mantel from Top
Ref. of Comb. Chamber
A
19" (483mm)
B
17" (432mm)
C
15" (381mm)
D
13" (330mm)
E
11" (297mm)
Top View
Mantel Leg
CFM197
Front View
Side of Combustion
Chamber
Mantel
Ref.
Leg Depth
Ref.
F
10" (254mm)
G
8" (203mm)
H
6" (152mm)
I
4" (102mm)
J
2" (51mm)
Fig. 4b Combustible mantel leg minimum installation.

Hearth

A hearth is not mandatory; however, for aesthetic
purposes, we recommend installing a noncombustible
hearth that projects out 12" (305mm) or more from the
front of the fireplace.
Cold climate installation recommendation:
When installing this unit against a
noninsulated exterior wall or chase, it is
mandatory the outer walls be insulated to
conform to applicable insulation codes.
J
I
H
G
F
K
L
M
N
O
Mantel
Leg
CFM170
Mantel Leg From Side
of Comb. Opening
K
11¹⁄₂" (292mm)
L
9¹⁄₂" (241mm)
M
7¹⁄₂" (191mm)
N
5¹⁄₂" (140mm)
O
3¹⁄₂" (89mm)
10006326