Locating Your Fireplace; Clearance To Combustibles; Mantels - Majestic 33LDVT Installation Instructions And Homeowner's Manual

Table of Contents

Advertisement

LDVT Series Direct Vent Gas Fireplace

Locating Your Fireplace

E
Y
D
Y
F
Fig. 2 Locate gas fireplace.
A - Flat on wall
B - Cross corner
D - *Room divider
E - *Flat on wall corner
Y - 6" minimum
Note (Fig. 2):
** Island (C) and Room Divider (D) installation is possible as long
as the horizontal portion of the vent system (X) does not exceed
20' (6m). See details in manual Venting Section.
* When you install your fireplace in(D) Room divider or (E) Flat
on wall corner positions (Y), a minimum of 6" (152mm) clearance
must be maintained from the perpendicular wall and the front side
edge of the fireplace. See (Y) in Fig. 2.

Clearance to Combustibles

Top of Unit to Ceiling ................................. 36" (914 mm)
Appliance
Top .......................................................... 0" (0 mm)
Bottom ..................................................... 0" (0 mm)
Side ......................................................... 0" (0 mm)
Back ........................................................ 0" (0 mm)
Venting
Concentric sections of DV Vent
Top, bottom & sides .............................. 1" (25 mm)
Flex Vent................................................... 7/8" (22 mm)

Mantels

The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This also
applies to the distance between the mantel leg (if fitted)
and the fireplace.
For the correct mounting height and widths refer to Figures
3a and 3b.
The fitting of a bay window trim kit does not effect the
distances and reference points referred to in the diagram
and chart.
Noncombustible mantels and legs may be installed at
any height and width around the appliance.
When using paint or lacquer to finish the mantel, such
paint or lacquer must be heat resistant to prevent
discoloration.
6
A
B
X
C
X
B
LU584-T
Locating unit
C - **Island
12/18/02 djt
F - Chase installation
A
B
C
D
CFM146
Mantel Chart
Mantel Shelf
CFM146
DV Mantel Chart
Ref. or Breast Plate Ref.
7/5/01 sta
Depth
V
10" (254 mm)
A
W
8"
(203 mm)
B
X
6"
(152 mm)
C
Y
4"
(101 mm)
D
Z
2"
(51 mm)
E
Fig. 3a Combustible mantel minimum installation.
Black
Surround
Face
Side of
Combustion Chamber
CFM164a
Mantel Leg Chart
06/22/01 sta
Mantel
Ref.
Leg Depth
F
10"
(254 mm)
CFM170
G
8"
(203 mm)
DV Builder Front
H
6"
(152 mm)
View
I
4"
(101 mm)
J
2"
(51 mm)
Fig. 3b Combustible mantel leg minimum installation.
V
W
X
Y
Z
3/4" (19 mm) Scribe
Moulding for use with
Vermont Castings
Group Cabinets
E
Fireplace
Top Louvre
Assembly
Top of
Combustion
Chamber
Mantel from Top
of Combustion Chamber
36/39/43 LDVT
33LDVT
17" (432 mm) 16¹⁄₂" (419 mm)
15" (381 mm) 14¹⁄₂" (368 mm)
13" (330 mm) 12¹⁄₂" (318 mm)
11" (279 mm) 10¹⁄₂" (267 mm)
9" (229 mm)
8¹⁄₂" (216 mm)
3/4" (19 mm) Scribe
Moulding for use with
Vermont Castings Group
Cabinets
J
I
H
G
Mantel
Leg
K
L
M
N
O
CFM170
Mantel Leg FromSide
Ref.
of Comb. Opening
K
11¹⁄₂"
(292 mm)
L
9¹⁄₂"
(241 mm)
M
7¹⁄₂"
(191 mm)
N
5¹⁄₂"
(140 mm)
O
3¹⁄₂"
(89 mm)
10007852