NVB Series B-Vent Gas Fireplace

Clearance to Combustibles

Appliances
Top ..........................................................0" (0 mm)
Bottom .....................................................0" (0 mm)
Side .........................................................0" (0 mm)
Back ........................................................0" (0 mm)
Perpendicular Sidewall ...........................0" (0 mm)
Top of unit to ceiling ..........................36" (914 mm)
Front of unit to combustibles .............36" (914 mm)
Venting
B-Vent ...................................................1" (25 mm)

Mantels\

The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
fitted) and the fireplace.
For the correct mounting height and widths refer to
Figures 5a and 5b
The distances and reference points are not affected by
the fitting of a bay window front trim kit.
f i r e - p a r t s . c o m
Noncombustible mantels and legs may be installed at
any height and width around the appliance.
When using paint or lacquer to finish the
mantel, such paint or lacquer must be heat
resistant to prevent discoloration.
Side View
A
B
C
D
Ref.
Mantel
Shelf Depth
V
14" (356 mm)
W
12" (305 mm)
X
10" (254 mm)
Y
8" (203 mm)
Z
1¹⁄₂" (38 mm)
Fig. 5a Mantel clearances.
6
V
W
X
Y
Z
E
Fireplace
Top of Combustion
Chamber
CFM146
Ref.
Mantel From Top
CFM146
of Comb. Chamber
DV Mantel Chart
7/5/01 sta
A
18"
(457 mm)
B
16"
(406 mm)
C
14"
(356 mm)
D
12"
(305 mm)
E
8"
(203 mm)
Black Sur-
Mantel
round Face
Leg
CFM164
CFM164a
Side of
Mantel Leg Chart
Combustion Chamber
06/22/01 sta
Ref.
Mantel
Leg Depth
CFM170
F
14" (356 mm)
DV Builder Front
G
12" (305 mm)
View
H
10" (254 mm)
I
8" (203 mm)
J
1¹⁄₂" (38 mm)
Fig. 5b Combustible mantel leg minimum installation.

Hearth

A hearth is not mandatory but is recommended for
aesthetic purposes. We recommend a noncombustible
hearth.

Insulating For Cold Climates

When an appliance is installed in a chase or an outside
wall, the enclosure should be insulated like any other
wall of the home. Insulation should be installed under
the appliance and on the inside of the exterior walls.
In a chase, it is a good idea to install a firestop at the
first ceiling level above the appliance. Also, install insu-
lation on the side walls. Insulation may then be placed
above the ceiling to assure the space around the appli-
ance is protected. Refer to Page 8, Figure 7.
J
I
H
G
F
K
L
M
N
O
CFM170
Ref.
Mantel Leg From
of Comb. Opening
K
14" (356 mm)
L
12" (305 mm)
M
10" (254 mm)
N
8" (203 mm)
O
1¹⁄₂" (38 mm)
7412950