Clearance to Combustibles
Appliances
Top .......................................... 0" (0mm)
Bottom ..................................... 0" (0mm)
Side ......................................... 0" (0mm)
Back ......................................... 0" (0mm)
Perpendicular Sidewall ............ 0" (0mm)
Top of unit to ceiling ................ 36" (914mm)
Front of unit to combustibles ... 36" (914mm)
Venting
B-Vent ...................................... 1" (25mm)
Mantels
The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
fitted) and the fireplace.
For the correct mounting height and widths refer to
Figures 2a, 2b and the Mantel Chart below.
The distances and reference points are not affected by
the fitting of a bay window front trim kit.
Noncombustible mantels and legs may be installed at
any height and width around the appliance.
When using paint or lacquer to finish the mantel,
such paint or lacquer must be heat resistant to
prevent discoloration.
Side View
A
B
C
D
Bottom of Door Trim
Mantel Chart
Mantel Shelf
Ref.
or Breast Plate Ref. of Comb. Chamber
V
10" (254mm)
W
8" (203mm)
X
6" (152mm)
Y
4" (101mm)
Z
2" (50mm)
Fig. 2a Combustible mantel minimum installation.
20003565
Vermont Castings Majestic Products NV360/580 Series
\
V
W
X
Y
Z
E
Fireplace
Louvre Assembly Top
Top of Comb. Chamber
CFM146
Mantel from Top
A
19" (483mm)
B
17" (432mm)
C
15" (381mm)
D
13" (330mm)
E
11" (279mm)
Black
Surround
Face
Mantel
Leg
CFM164a
Side of Combus-
tion Chamber
Mantel
Ref.
Leg Depth
F
10" (254mm)
G
8" (203mm)
H
6" (152mm)
I
4" (101mm)
J
2" (50mm)
Fig. 2b Combustible mantel leg minimum installation.
Hearth
A hearth is not mandatory but is recommended for
aesthetic purposes. We recommend a noncombustible
hearth.
Cold climate installation recommendation:
When installing this unit against a non-
insulated exterior wall or chase, it is
mandatory that the outer walls be
insulated to conform to applicable
insulation codes.
J
I
H
G
K
L
M
N
O
Man-
tel
Leg
CFM170
Mantel Leg from Side
Ref.
of Comb. Opening
K
11¹⁄₂" (292mm)
L
9¹⁄₂" (241mm)
M
7¹⁄₂" (191mm)
N
5¹⁄₂" (140mm)
O
3¹⁄₂" (89mm)
F