installation & connection

` camera wiring interface Board

For the camera wiring, please refer to the picture below.
Alarm
Select Normal Open in the setup menu.
`
J
-
The sensor input is activated during a short for contact type, or when it is at "Low" level for
the active type.
Select Normal Close from the Setup menu.
`
-
The sensor input is activated when open for the contact type or when in high impedance
state (open collector) for the active type.
The maximum power capacity of the alarm outputs is DC +40V and 80 mA.
`
When connecting alarm input and output cables, be sure to connect one cable to each
`
terminal respectively.
To connect products over the camera's capacity, please use an additional relay device.
`
Connecting the power connector and GND incorrectly to the alarm out port may lead to fire
`
and damage the camera.
20_ installation & connection
Video
Audio
Output
Alarm
output
Alarm Input
ETHERNET
Audio
IN
OUT
Communications
D+
D-
TX+
TX-
Refer to Control Signal
Connection Diagram
Power Supply
AC24V 2.5A
Power Input
Ground
GND