SW2 Pin No.
1~4
Protocol Settings
5~6
Baud Rate Settings
7
Transfer Method (RS-485/422) Settings
8
Termination Settings 1
9
Termination Settings 2
10
Response Mode Settings
• protocol Settings
Select a communication protocol for the camera.
No.
Protocol
1
Samsung(Default)
2
Pelco-D
3
Pelco-P
4
Samsung Elec.
5
Panasonic
6
Vicon
7
Honeywell
8
AD
9
GE
10
BOSCH
11
Reserved
12
Reserved
13
Reserved
14
Reserved
15
Reserved
16
Reserved
Purpose
SW2-#1
SW2-#2
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
SW2-#3
SW2-#4
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
English _115