Table 6 Transmitter Overpressure Ratings - Honeywell ST 3000 User Manual

Smart transmitter release 300 and smart field communicator model sts103
Hide thumbs Also See for ST 3000:
Table of Contents

Advertisement

3.3
Considerations for ST 3000 Transmitter,
Pressure ratings
Table 6
Transmitter Maximum Allowable Working Pressure (MAWP) Ratings
Transmitter Type
Draft Range
Differential Pressure
Gauge Pressure
Flange Mount
Remote Seal
Absolute Pressure
Note: Maximum Allowable Working Pressure (MAWP) may vary with materials of construction and process
temperature. For more specific information, refer to the appropriate Specification and Model Selection
Guide. In transmitters with Graphite Gaskets, rating of 50 psi remains unchanged while ratings of 4500
psi are reduced to 3625 psi (250 bar). Flange Adapters with Graphite Gaskets have a 3000 psi rating.
NOTE: To convert bar values to kilopascals (kPa), multiply by 100.
For example, 3.5 bar equals 350 kPa.
February 2012
ST 3000 Release 300 and SFC Model STS103 User's Manual
Table 6 lists maximum working pressure for a given transmitter Upper
Range Limit (URL).
The maximum allowable working pressure (MAWP) is the pressure
used for the approval body safety calculations.
Upper Range Limit
(URL)
10 inches H
O (25
2
mbar)
400 inches H
O (1 bar)
2
600 inches H
O (1.5
2
bar)
100 psi (7 bar)
3,000 psi (207 bar)
100 psi (7 bar)
300 psi (21 bar)
500 psi (35 bar)
3,000 psi (207 bar)
6,000 psi (415 bar)
10,000 psi (690 bar)
400 inches H2O (1 bar)
100 psi (7 bar)
400 inches H2O (1 bar)
100 psi (7 bar)
780 mmHg Absolute
(1 bar)
500 psia (35 bar)
3,000 psia (210 barA)
Maximum Working
Pressure Rating
50 psi (3.5 bar)
4,500 psi (310 bar)
4,500 psi (310 bar)
4,500 psi (310 bar)
4,500 psi (310 bar)
100 psi (7 bar)
300 psi (21 bar)
500 psi (35 bar)
3,000 psi (207 bar)
6,000 psi (415 bar)
10,000 psi (690 bar)
Per selected flange
and material
(ANSI/ASME 150#,
300#, DN PN40)
Lesser MAWP of
either Remote Seal
selected or transmitter
pressure rating
780 mmHg Absolute
(1 bar)
500 psia (35 bar)
3,000 psia (210 barA)
Continued
Overpressure Rating
50 psi (3.5 bar)
(No overpressure
protection is provided)
4,500 psi (310 bar)
4,500 psi (310 bar)
4,500 psi (310 bar)
4,500 psi (310 bar)
150 psi (10.3 bar)
450 psi (31 bar)
500 psi (35 bar)
3,000 psi (207 bar)
9,000 psi (620 bar)
15,000 psi (1034 bar)
Full vacuum to 1550
mmHg Absolute (2 bar)
750 psia (52 bar)