Installation

You must be aware of the
following safety requirements &
regulations
Prior to installation, ensure that the local distribution
conditions (nature of the gas and gas pressure) and the
adjustment of the appliance are compatible.
This appliance shall be installed in accordance with the
regulations in force and only in a well ventilated space.
Read the instructions before installing or using this
appliance.
In the UK
the regulations and standards are as
follows:-
In your own interest and that of safety, it is law that all
gas appliances be installed by competent persons. Gas
Safe registered installers undertake to work to safe and
satisfactory standards. Failure to install the appliance
correctly could invalidate any warranty or liability claims
and lead to prosecution. The cooker must be installed in
accordance with
All relevant British Standards / Codes of
Practice, in particular BS 5440 Part 2 2000,
or Natural Gas - BS 6172 : 1990 and BS
6891 : 1998
For LP Gas - BS 5482-1:1994 (when the
installation is in a permanent dwelling), BS
5482-2:1977, (when the installation is in a
caravan or other non permanent dwelling), or
BS 5482-3:1999 , (when the installation is in
a boat).
The Gas Safety (Installation and Use)
regulations 1998.
The relevant Building / IEE regulations.
Conversion
All models are supplied set for use on group H natural gas. A conversion kit from NG to LP gas is supplied with the
cooker.
For conversion, see the instructions that are supplied with the conversion kit. After converting the appliance please
attach the Gas Conversion sticker over the appropriate area of the data badge, this will identify the gas type the
appliance is now set for.
This appliance is designed for domestic cooking only. Use for any other purpose could invalidate any
warranty or liability claim.
In IE
, the installation must be carried out by a
Competent Person and installed in accordance with the
current edition of I.S.813 "Domestic Gas Installations",
the current Building Regulations and reference should
be made to the current ETCI rules for electrical
installation.

Provision of Ventilation

This appliance is not connected to a combustion
products evacuation device. Particular attention shall be
given to the relevant requirements regarding ventilation.
In the UK
The room containing the cooker should have an air
supply in accordance with BS 5440 Part 2 : 2000. All
rooms require an openable window or equivalent, while
some rooms require a permanent vent in addition to the
openable window. The cooker should not be installed
in a bedsitting room with volume less than 20m
installed in a room of volume less than 5m
of effective area 100cm
a room of volume between 5m
of effective area 50cm
exceeds 11m
, no air vent is required.
3
If there are other fuel burning appliances in the same
room, BS 5440 Part 2 : 2000 should be consulted to
determine the requisite air vent requirements.
In IE
Reference should be made to the current edition of IS
813 which makes clear the conditions that must be met
to demonstrate that sufficient ventilation is available.

Location of Cooker

The cooker may be installed in a kitchen/kitchen diner
but NOT in a room containing a bath or shower.
NOTE:
An appliance for use on LPG shall not be installed in
a room or internal space below ground level. e.g. in
a basement.
22
an air vent
3
is required; if it is installed in
2
and 10m
, an air vent
3
3
is required; while if the volume
2
. If it is
3