Reports; Start-Up Report - Buderus 800-24 Installation And Servicing Instructions

Wall hung condensing
Hide thumbs Also See for 800-24:
Table of Contents

Advertisement

7

Reports

7.1

Start-up report

Please check off the start-up tasks carried out and enter the corresponding readings, while making sure that you carefully follow
the instructions.
Initial start-up tasks
1.
Note down gas characteristics:
2.
Has a leak test been carried out?
(see chapter 2.1.5 on page 23)
3.
Check combustion air/flue gas connection
4.
Check the boiler equipment (change to another type of gas if
necessary)(see chapter 2.2.1 on page 24)
5.
Carry out adjustment settings
(see chapter 2.2.2 on page 25)
6.
Measure the gas supply pressure (flow pressure)
(see chapter 2.2.3 on page 27)
7.
Check and set the gas/air ratio
CO
-content:
2
(see chapter 2.2.4 on page 28)
8.
Check for leaks with system in operational condition
(see chapter 2.2.5 on page 30)
9.
Record readings
Flow pressure
Exhaust-gas temperature, gross t
Air temperature t
L
Flue temperature, net t
Carbon dioxide (CO
Exhaust-gas losses q
Carbon monoxide content (CO), free from air
(see chapter 2.2.6 on page 30)
10.
Testing the operation
Measure the ionisation current
(see chapter 2.2.7 on page 30)
11.
Fit the boiler casing
(see chapter 2.2.8 on page 31)
12.
Instruct the user, hand over the documentation
(see chapter 2.2.9 on page 31)
13.
Confirm commissioning (see Benchmark)
Confirmation of professional commissioning
(Company stamp, signature)
Subject to modifications resulting from technical improvements !
Installation and servicing instructions condensing gas boiler 800 - 24/29/43/60 and 800 - 24T25/29T25 H/V • edition 02/2006
Wobbe index
Operational heat value
under full load
under partial load
A
- t
A
L
) or oxygen (O
) content
2
2
A
Reports
Remarks or measurement readings
––––––––––––––––––––
––––––––––––––––––––
––––––––––––––––––––
––––––––––––––––––––
––––––––––––––––––––
––––––––––––––––––––
––––––––––––––––––––
––––––––––––––––––––
––––––––––––––––––––
––––––––––––––––––––
––––––––––––––––––––
––––––––––––––––––––
––––––––––––––––––––
––––––––––––––––––––-
Buderus • http://buderus-domestic.co.uk
7
kWh/m³
kWh/m³
mbar
Pa
%
%
Pa
°C
°C
°C
%
%
ppm
µA
63

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents