2.2.2
Settings
Setting the flow temperature
Set the controller (fig. 31, item 2) to the desired maximum
flow temperature in accordance with the system design
and table 6.
Factory setting = 80 °C (controller poition 10).
Subject to modifications resulting from technical improvements !
Installation and servicing instructions condensing gas boiler 800 - 24/29/43/60 and 800 - 24T25/29T25 H/V • edition 02/2006
Initial start-up
1 2 3
fig. 31 Controls
Key to fig. 31
Item 1:
Main switch
Item 2:
Flow temperature controller
Item 3:
Domestic hot water temperature controller
Item 4:
Jumper 11/50 kW to limit capacity
Item 5:
Pump over-run time switch
Item 6:
Heating capacity controller
Item 7:
Cover for second control level
Controller position
1
2
3
4
5
6
7
8
9
10
Table 6
Flow temperature
4 5
11
kW
0
1
1
2
10
1
10
1
10
7
Flow temperature in °C
40
44
48
53
58
62
67
71
76
80
Buderus • http://buderus-domestic.co.uk
2
6
25