4
Maintenance
Push up the fan (fig. 46, item 1).
Pivot the lower end of the fan forward (fig. 46, item 2) and
take it out downwards and forwards (fig. 46, item 3).
Loosen both retaining clamps (fig. 47, item 2) of the burner
cover and remove the burner cover and burner
(fig. 47, item 3).
Cleaning by using a brush and compressed air
Pull the syphon away from the condensate plate
(fig. 47, item 1).
Loosen the connection to the condensate water bypass
(fig. 47, item 6).
Loosen the retaining clamps (fig. 47, item 4) of the
condensate plate and remove the condensate plate
(fig. 47, item 5).
Pull out the baffle plate (fig. 48).
Subject to modifications resulting from technical improvements !
34
Installation and servicing instructions condensing gas boiler 800 - 24/29/43/60 and 800 - 24T25/29T25 H/V • edition 02/2006
fig. 46 Removing the fan
2
4
1
2
3
4
5
6
7
8
9
10
11
12
fig. 47 Removing the cover and condensate plate
fig. 48 Baffle plate
1
3
2
3
5
1
6
2
1
3
4
24 VAC
5
- max 6 VA
0
24 VAC
6
Buderus • http://buderus-domestic.co.uk