Error Messages - KVH Industries RV1 User Manual

Hide thumbs Also See for RV1:
Table of Contents

Advertisement

Error Messages

If any of the Status indicators on the Home page of the web interface
are flashing orange, flashing red, or solid red, click on it to view the
error message.
Figure 8-4 Example of Error Messages under Status Indicators
The table below lists all of the possible error messages. Many of these
faults should only be repaired by a KVH-certified technician; contact
KVH Technical Support for assistance (see
page
93).
Error
100
101
102
104
105
106
Description
There is an open circuit in the DC power wires running
between the antenna and the TV-Hub. The TV-Hub detects
no DC current feed to the antenna. Check the RF1 cable
between the antenna and the TV-Hub.
There is a short circuit in the DC power wires running
between the antenna and the TV-Hub. The TV-Hub detects
an overload condition. Check the RF1 cable between the
antenna and the TV-Hub.
The TV-Hub is not providing the proper DC voltage to the
antenna (should be 37.8-46.2 VDC). Contact KVH.
The software update file you selected is corrupt. Try a new
update file.
The TV-Hub is unable to read from or write to its
EEPROM. Contact KVH.
The TV-Hub has lost communications with the antenna.
Check the RF1 cable between the antenna and the TV-Hub.
TracVision RV1 User's Guide
Troubleshooting
"Technical Support" on
85

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tracvision rv1