KVH Industries RV1 User Manual page 81

Hide thumbs Also See for RV1:
Table of Contents

Advertisement

TracVision RV1 User's Guide
Troubleshooting
86
Error
Description
107
The TV-Hub internal temperature exceeds acceptable
limits. If the problem persists, you might need to relocate
the unit to an area that provides better ventilation.
108
An automated reboot of the TV-Hub is in process to
resolve low memory. No action is required.
109
The TV-Hub is running low on memory but it should be
able to recover without a reboot.
111
The TV-Hub is unable to initialize its built-in wireless
access point (WAP). Contact KVH.
119
The 24 VDC power to the internal SWM module is out of
range. DIRECTV outputs are disabled. Contact KVH.
124
The software update file you selected is not valid for your
antenna model. Try a new update file.
128
The software update failed. Retry updating the software. If
it fails again, check the RF1 cable between the antenna and
the TV-Hub.
129
One of the TV-Hub's power supplies is out of range.
Contact KVH.
130
The TV-Hub DC input voltage is out of range (should be
10-30 VDC). Check the power source that is supplying DC
power to the TV-Hub.
131
The TV-Hub detects no DC current feed to the antenna,
following a period of normal operation. Check the RF1
cable between the antenna and the TV-Hub.
200
The antenna is not receiving adequate DC power from the
TV-Hub. Check the RF1 cable between the antenna and the
TV-Hub.
203
The antenna's main board has lost communications with
the azimuth and elevation motors. Contact KVH.
204
The antenna's main board has lost RF communications.
Contact KVH.
205
The antenna's azimuth motor has a power failure. Contact
KVH.
206
The antenna's azimuth motor or limit switch failed.
Contact KVH.