Setup

Operations & Installation Guide – DOC. 6845E
4.3" Touch Screen with Room Scheduling

Network Wiring

When wiring the Ethernet network, consider the following:
Use Crestron Certified Wire.
Use Crestron power supplies for Crestron equipment.
Provide sufficient power to the system.
CAUTION: Insufficient power can lead to unpredictable results or damage
to the equipment. Please use the Crestron Power Calculator to help calculate
how much power is needed for the system (www.crestron.com/calculators).
Unlike other Crestron network devices, the TPMC-4SM does not use Cresnet
communications between the device and the control system. The TPMC-4SM
requires the use of a high-speed Ethernet connection for control system
communications.
For general information on connecting Ethernet devices in a Crestron system, refer to
the latest version of the Crestron e-Control

Identity Code

NOTE: The latest software can be downloaded from the Crestron Web site
(www.crestron.com/software).
The IP ID is set within the TPMC-4SM's IP table using Crestron Toolbox™. For
information on setting an IP table, refer to the Crestron Toolbox help file. The IP IDs
of multiple TPMC-4SM devices in the same system must be unique.
When setting the IP ID, consider the following:
The IP ID of each unit must match an IP ID specified in the Crestron
Studio™ or SIMPL Windows program.
Each device using IP to communicate with a control system must have a
unique IP ID.
NOTE: In RoomView
automatically set to 02.
4.3" Touch Screen with Room Scheduling: TPMC-4SM • 11
Reference Guide (Doc. 6052).
®
OOTBF mode, the TPMC-4SM's IP ID is
for