Regency ULTIMATE U39 Owners & Installation Manual page 17

Direct vent freestanding gas stove
Hide thumbs Also See for ULTIMATE U39:
Table of Contents

Advertisement

945BG
45
O
Elbow-Swivel-Black
O
990
90
Elbow Galv.
O
990B
90
Elbow-Black
O
990G
90
Elbow-Swivel Galv.
990BG
90
O
Elbow-Swivel-Black
991
High Wind Term. Cap (Vertical)
980
Vertical Term. Cap
984
Horiz. Sq. Term. Cap
985
Horiz. Sq. High Wind Term. Cap
982
Snorkel-14" Rise Term.Cap
981
Snorkel-36" Rise Term.Cap
940
Wall Thimble-Support/Box
941
Cathedral/Ceiling-Support/Box
3951
Brass Trim-Wall Thimble/
Ceiling Support
963
Firestop Spacer
943
Flashing 0/12-6/12
943S
Flashing 7/12-12/12
953
Storm Collar
950
Vinyl Siding Standoff
988
Wall Strap
942
Wall Thimble
Parts not supplied by Dura-Vent
946-523/P AstroCap
946-206
Vinyl Siding Shield for AstroCap
946-506/P Vent Guard (Optional)
640-530/P Riser Vent Terminal (Optional)
946-205
Vinyl Siding Shield for Riser
Vent Terminal
946-208
Horizontal Vent Guard (Riser Vent)
DURA-VENT
HORIZONTAL
TERMINATIONS
1) Set the unit in its desired location. Check
to determine if wall studs or roof rafters
are in the way when the venting system is
attached. If this is the case, you may want
to adjust the location of the unit.
2) Direct Vent pipe and fi ttings are designed
with special twist-lock connections to
connect the venting system to the appliance
fl ue outlet. A twist-lock appliance adaptor
is installed on the unit at the factory.
Assemble the desired combination of pipe
and elbows to the appliance adaptor with
pipe seams oriented towards
the wall or ceiling, as much out
of view as possible.
The fi nal positioning
o
of the pipe and 90
elbow assembly is
determined by the
mounting orientation
of the adaptor on
the stove and twist-
locked for a solid
connection.
Regency
®
U39 ULTIMATE Direct Vent Freestanding Gas Stove
Note:
a) Twist-lock procedure: Four indentations,
located on the female ends of pipes and
fi ttings, are designed to slide straight
onto the male ends of adjacent pipes
and fi ttings, by orienting the four pipe
indentations so they match and slide in
to the four entry slots on the male ends
(diagram 1). Push the pipe sections
completely
together, then twist-lock
one section clockwise approximately
one-quarter turn, until the two sections
are fully locked. The female locking lugs
will not be visible from the outside on
the Black Pipe or fi ttings. They may be
located by examining the inside of the
female ends. Apply sealant "Mill-Pac" to
inner pipe and high temp silicone sealant
to outer pipe on every twist-lock joint.
Hint: Apply
silicone to female
end.
Diagram 1
b) Horizontal runs of vent must be
supported every three feet. Wall straps
are available for this purpose.
3) With the pipe attached to the stove, slide
the stove into its correct location, and mark
the wall for a 10" x 10" (inside dimensions)
square hole. The center of the square
hole should line up with the centerline of
the horizontal pipe, as shown in diagram
2. Cut and frame the 10 inch square hole
in the exterior wall where the vent will be
terminated. If the wall being penetrated is
constructed of non-combustible material,
i.e. masonry block or concrete, a 7" diameter
hole is acceptable.
Diagram 2
INSTALLATION
Note:
a)
The horizontal run of vent should have
a 1/4 inch rise for every 1 foot of run
towards the termination. Never allow the
vent to run downward. This could cause
high temperatures and may present the
possibility of a fi re.
b) The location of the horizontal vent
termination on an exterior wall must
meet all local and national building
codes, and must not be blocked or
obstructed. See instructions in the
"External Vent Terminal Locations"
section.
c) Snorkel Terminations:
For installations requiring a vertical rise
on the exterior of the building, 14-inch
and 36-inch tall Snorkel Terminations
as shown in Dia. 3 are available, as
well as the standard Riser Vent, see
Dia. 3a. Follow the same installation
procedures as used for standard
Horizontal Termination. NEVER install
the snorkel upside down.
*Dia 3, 3a & 4: As specifi ed in
CGA B149 Installation Code.
Local codes or regula-
tions may require dif-
ferent clearances.
Diagram 3
NOTE: For Snorkel terminations in ABOVE
grade installations, follow national or local
code requirements.
Note: Riser Vent
is only for use
in above grade
terminations.
Diagram 3a
17