Symbologies
Code 128 — continued

Minimum/Maximum Code Length

Many symbologies have their own maximum and minimum code
length, which can be set to qualify data entry. The length is defined as
the actual bar code data length to be sent. Labels with lengths below the
minimum or above the maximum will be rejected. If the maximum code
length is set to zero, the global maximum is in effect. If the minimum
code length is set to zero, the global minimum is in effect.
Ensure that the minimum length setting is not greater
than the maximum length setting; otherwise, all the
labels of the symbology will be unreadable. You can set
the same value for both minimum and maximum length
NOTE
to force decoding of only bar codes of a certain length.
START
MODE
Set Maximum
Length
Set Minimum
Length
SET