Removal Of Sound Insulation And Reactor - Daikin Super Multi NX C-Series Service Manual

Super multi nx c-series
Table of Contents

Advertisement

SiE12-411
1.7

Removal of Sound Insulation and Reactor

Procedure
Step
1
Release the clip fixing
the compressor lead
wire.
2
Remove 2 screws of
the partition board, and
move the board
leftward.
3
Remove the noise
insulation (outer).
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Clip
Noise insulation
(outer)
Outdoor Unit (80 / 90 Class)
" The partition board is not
removable as it is fixed with
the fitting screw in the rear
bottom.
Partition board
fitting screw
" Carefully remove the noise
insulation, which is easily
torn in the piping section.
Points
233