Juniper J-series Services Router J2320 Getting Started Manual page 218

Services router
Hide thumbs Also See for J-series Services Router J2320:
Table of Contents

Advertisement

J2320, J2350, J4350, and J6350 Services Router Getting Started Guide
NOTE: Each power supply must be connected to a dedicated AC power feed. For
information about connecting to AC power sources, see "Connecting
Power" on page 122.
6.
7.
Figure 90: Installing an AC Power Supply
Replacing DC Power Supply Cables
To replace a power cable for a DC power supply:
1.
CAUTION: A licensed electrician must attach a cable lug to the power cable that you
supply. A cable with an incorrectly attached lug can damage the router (for example,
by causing a short circuit).
2.
3.
4.
196
Replacing Power System Components
Verify that the power cord does not block access to router components or drape
where people might trip on it.
Press and release the power button to power on the router. Verify that the
LED lights steadily.
Locate a replacement power cable and a lug that meet the specifications defined
in "Chassis Grounding" on page 121 and "DC Power, Connection, and Power
Cable Specifications" on page 108.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and
connect the strap to the ESD point on the chassis, or to an outside ESD point if
the router is disconnected from earth ground. For more information about ESD,
see "Preventing Electrostatic Discharge Damage" on page 249.
Press and release the power button to power off the Services Router. Wait for
the
POWER
LED to turn off.
Ensure that the voltage across the DC power source cable leads is 0 V and that
the cable leads cannot become active during installation.
POWER

Advertisement

Table of Contents
loading

This manual is also suitable for:

J6350J2350J4350

Table of Contents