Setting
Address
Utility Mode (4,5)
0e0095
Tel-Fax switching
Utility Mode
Special Setting
0e0096
Ring Back Tone parameter
(0 - 3,5 - 7)
Utility Mode Spe-
cial Setting
0e0097
International com mode operation
(6,7)
Utility Mode Spe-
cial Setting
0e0098
Starting speed in international mode (V29 modem)
(0,1,3,4)
Utility Mode Spe-
Starting speed in international mode (V17 or V33
cial Setting
0e0099
modem)
(4 - 7)
Utility Mode Spe-
0e009a
Starting speed in international mode (V34)
cial Setting
---
0e009b
CD OFF timer
---
0e009c
CD ON integration time
Utility Mode Spe-
cial Setting
0e009d
Symbol rate maximum allowable value
(0 - 3,7)
Utility Mode Spe-
0e009e
Symbol rate selection criteria
cial Setting
Utility Mode Spe-
cial Setting
0e009f
Primary channel data rate selection criteria
(0 - 3)
---
0e00a0
V34 primary channel fallback
---
0e00a1
V34 control channel fallback
---
0e00a2
V34 off Rx-V34 off time after error
---
0e00a3
V34 off Rx-V17 OK Rx times to reset V34 off Rx
---
0e00a4
(Inhibit of) V34 off Rx-Function ON/OFF
Item
bit7
bit6
RBT format
000: None
001: Japan
010: US
011: UK
100: Germany
101 to 111: Others
DIS waiting fre-
quency
Overseas com-
0: Always 1 time
munication
1: Twice in over-
0: No
seas communica-
1: Yes
tion
14400bps/v.17
12000bps/v.17
33600bps/V.34
31200bps/V.34
CD OFF timer (Unit: 100 ms, HEX)
CD ON integration time (Unit: 100 ms. HEX)
V34 controlled ch
data rate
0:1200
1:2400
Attenuation distortion property (-6dBto+6dB)
0000:-6
0001:-5
0010:-4
0111:+1
1000:+2
1001:+3
V.34 reception gain correction (-4.0dBto+3.5dB)
0000:0
0001:+0.5
0010:+1.0
0110:+3.0
0111:+3.5
1000:-4.0
1100:-2.0
1101:-1.5
1110:-1.0
No. of frame errors subjected to fallback (HEX)
EQMVAL value for fallback (HEX)
Timer value after V34 reception error used to reset V34 off reception (min, HEX)
(Valid only when transmission side cannot be specified)
No. of continuous success of V17 receptions used to reset V34 off reception after V34 reception error (times, HEX)
(Valid only when transmission side can be specified with Caller ID)
V34off function for
manual reception
0: Enable
1: Disable
Contents
bit5
bit4
bit3
TEL/FAX switching mode
00: No
10: Normal (RBT transmission)
CED transmitted
upon Tel/Fax
RBT transmission level (HEX)0 to -15 dBm
switching
9600bps/V.29
7200bps/V.29
9600bps/v.17
7200bps/v.17
28800bps/V.34
26400bps/V.34
24000bps/V.34
Max. allowable symbol speed
0000:2400
0001:Reserved
0010:2800
0011:3000
0100:3200
0101:3429
Band end S/N (-6dBto+6dB)
0011:-3
0100:-2
0101:-1 0110:0
0000:-6
0001:-5
1010:+4
1011:+5
1100:+6
0111:+1
1000:+2
Primary channel data rate selection criteria (-8dBto+7dB)
0011:+1.5
0100:+2.0 0101:+2.5
0000:-8
0001:-7
1001:-3.5
1010:-3.0 1011:-2.5
0110:-2
0111:-1
1111:-0.5
1100:+4
1101:+5
bit2
bit1
bit0
4800bps/V27ter
2400bps/V27ter
21600bps/V.34
19200bps/V.34
16800bps/V.34
0010:-4
0011:-3
0100:-2
0101:-1 0110:0
1001:+3
1010:+4
1011:+5
1100:+6
0010:-6
0011:-5
0100:-4
0101:-3
1000:0
1001:+1
1010:+2
1011:+3
1110:+6
1111:+7
V34 off reset
mode = No. of
V34 off reset
successful contin-
mode = Time (ID
uous V17 recep-
cannot be speci-
tions (ID
fied)
specified)
0: Enable
0: Enable
1: Disable
1: Disable
Default
North Amer-
Japan
Europe
ica
0x00
0x00
0x00
0x2A
0x4A
0x68
0x40
0x40
0x40
0x02
0x02
0x02
0x10
0x10
0x10
0x20
0x20
0x20
0x14
0x14
0x14
0x06
0x06
0x06
0x05
0x05
0x05
0x66
0x66
0x66
0x08
0x08
0x08
0x03
0x03
0x03
0x40
0x40
0x40
0x0a
0x0a
0x0a
0x0a
0x0a
0x0a
0x00
0x02
0x02