Setting
Address
---
0e00d3
Ringer detection frequency upper limits
---
0e00d4
Ringer detection frequency lower limits
---
0e00d5
Ringer ON time max. value
---
0e00d6
Ringer ON time min. value
---
0e00d7
Ringer OFF time max. value
Utility Mode Spe-
0e00d8
Ringer OFF time max. value
cial Setting
---
0e00d9
PB dial signal transmission time
---
0e00da
PB dial inter digit pause
---
0e00db
10pps pulse dial break rate
---
0e00dc
10pps pulse dial start time
---
0e00dd
10pps pulse dial blocking time
---
0e00de
10pps pulse dial inter digit pause
---
0e00df
20pps pulse dial break rate
---
0e00e0
20pps pulse dial start time
---
0e00e1
20pps pulse dial blocking time
---
0e00e2
20pps pulse dial inter digit pause
---
0e00e3
Flash dial relay ON time
---
0e00e4
Grounding dial relay ON time
Utility Mode Spe-
0e00e5
PB signal transmission level
cial Setting
Utility Mode Spe-
0e00e6
PB signal level difference (HL)
cial Setting
---
0e00e7
DcLoop integration time when CML is set to OFF
---
0e00e8
DcLoop integration time when CML is set to ON
Utility Mode Spe-
0e00e9
Pause time
cial Setting (0 - 2)
Item
bit7
bit6
Ringer detection frequency upper limit (unit: 1 Hz, HEX)
Ringer detection frequency lower limit (unit: 1 Hz, HEX)
Ringer ON time max. value (unit: 20 ms, HEX)
Ringer ON time min. value (unit: 20 ms, HEX)
Ringer OFF time max. value (unit: 100 ms, HEX)
Ringer OFF time min. value (unit: 100 ms, HEX)
PB dial signal transmission time (unit: 5 ms, HEX)
PB dial inter digit pause time (unit: 5 ms, HEX)
10pps pulse dial break rate (%, HEX)
10pps pulse dial start time (unit: 10 ms, HEX)
10pps pulse dial blocking time (unit: 10 ms, HEX)
10pps pulse dial inter digit pause (unit: 10 ms, HEX)
20pps pulse dial brake rate (%, HEX)
20pps pulse dial start time (unit: 10 ms, HEX)
20pps pulse dial blocking time (unit: 10 ms, HEX)
20pps pulse dial inter digit pause (unit: 10 ms, HEX)
Flash dial relay ON time (unit: 10 ms, HEX)
Grounding dial relay ON time (unit: 10 ms, HEX)
PB signal transmission level (unit: 1 dBm, HEX)
PB level difference (HL) (unit: 0.5 dBm, HEX)
DCLOOP integration time at CML relay OFF (unit: 5 ms, HEX)
DCLOOP integration time at CML relay ON (unit: 5 ms, HEX)
Contents
bit5
bit4
bit3
bit2
Pause time (unit: sec, HEX)
Default
North Amer-
bit1
bit0
Japan
ica
0x46
0x46
0x0c
0x0c
0x00
0x00
0x0a
0x0a
0x3c
0x3c
0x02
0x00
0x15
0x19
0x11
0x15
0x44
0x3d
0x0c
0x0c
0x0c
0x0c
0x50
0x50
0x44
0x3d
0x0c
0x0c
0x0c
0x0c
0x41
0x28
0x1e
0x1e
0x1e
0x1e
0x0a
0x0a
0x04
0x04
0x50
0x50
0x10
0x10
0x01
0x01
Europe
0x46
0x0c
0x00
0x08
0x46
0x00
0x15
0x11
0x3d
0x0c
0x0c
0x46
0x3d
0x0c
0x0c
0x44
0x1e
0x1e
0x06
0x04
0x50
0x10
0x01