OfficeServ 100 Installation Manual/Ed.00
Use MCP1: OfficeServ 100 System
The OfficeServ 100 can be programmed with a PC equipped with DPAP-PCMMC
connected to the MCP1 LAN port or via serial interface of the MCP1. PC programming
using the LAN port requires a data cross over cable if connecting directly to the LAN port
or a standard data cable if connecting via a LAN. In both cases the OfficeServ 100 IP
address and PC IP address(PCMMC ADDRESS) must be programmed in MMC 830.
The connection of hardware through the LAN port between the OfficeServ 100 system and
the programming PC for the MCP1 card is configured as shown below.
MCP1 LAN Port
LAN
OfficeServ 100
Prgramming PC
Figure 7.7 Programming PC Connection Through LAN Port for MCP Card
To program the OfficeServ 100 via a MCP1 serial port use an RS232C cable with
connections shown in Figure 7.5 or 7.6.