Table of Contents
loading

Summary of Contents for Samsung OfficeServ 100

  • Page 1: Installation Manual

    GABD-000100 OfficeServ 100 Installation Manual 10. 2004.
  • Page 2 This manual is proprietary to SAMSUNG Electronics Co., Ltd. and is protected by copyright. No information contained herein may be copied, translated, transcribed or duplicated for any commercial purposes or disclosed to third parties in any form without the prior written consent of SAMSUNG Electronics Co., Ltd.
  • Page 3: Introduction

    CHAPTER 1. Site Requirement This chapter describes site requirements for OfficeServ 100 system installation. CHAPTER 2. Installing Basic KSU and Expansion Cabinet This chapter describes how to install the OfficeServ 100 Key System Unit and expansion cabinet. CHAPTER 3. Installing Printed Circuit Cards This chapter describes how to install each card of OfficeServ 100 system.
  • Page 4: Conventions

    This chapter describes how to install the KDB(Keyset Daughter Board) to the phone. CHAPTER 9. Changing Software This chapter describes how to change software of OfficeServ 100 system. CHAPTER 10 Networking Description and Programming Procedure This chapter describes networking description and programming procedure of OfficeServ 100 system.
  • Page 5: Reference

    OfficeServ 100 Installation Manual/Ed.00 Reference OfficeServ 100 Programming Manual Introduces programming method for the OfficeServ 100 system users. Users can configure the system using the MMC(Man Machine Communication) program at the digital telephone. This manual describes how to use the MMC program.
  • Page 6 INTRODUCTION This page is intentionally left blank. © SAMSUNG Electronics Co., Ltd.
  • Page 7: Safety Concerns

    OfficeServ 100 Installation Manual SAFETY CONCERNS For product safety and correct operation, the following information must be given to the operator/user and shall be read before the installation and operation. Symbols Caution Indication of a general caution Restriction Indication for prohibiting an action for a product...
  • Page 8: Warning

    Before connecting the ground Unplug the power cord from the AC outlet before attempting to connect the ground. Hazardous voltage may cause death or injury. Observe extreme caution when working with AC power. Remove champ connectors. © SAMSUNG Electronics Co., Ltd.
  • Page 9: Caution

    When installing OfficeServ 100 Ensure that all wires and cable going to and coming from the OfficeServ 100 are properly routed. Do not cross fluorescent lights or connect lines parallel to the AC power line.
  • Page 10 SAFETY CONCERNS Before installing OfficeServ 100 Do not install the OfficeServ 100 system in close proximity to a fire sprinkler head or other sources of water. When installing OfficeServ 100 OfficeServ 100 system must not be exposed to direct sunlight, corrosive fumes, dust, constant vibration or strong magnetic fields such as those generated by motors and copy machines.
  • Page 11: Table Of Contents

    OfficeServ 100 Installation Manual TABLE OF CONTENTS INTRODUCTION Purpose ............................I Document Content and Organization....................I Conventions ............................II Reference ............................III Revision History ..........................III SAFETY CONCERNS Symbols ............................V Warning............................VI Caution ............................VII CHAPTER 1. Site Requirements Site Requirements........................1-1 Specification ..........................1-2 CHAPTER 2.
  • Page 12 3.14 SVMi-8 Card..........................3-13 3.15 ITM3 Card (only use in the iDCS 100 system) ............... 3-14 3.16 MCP1 Card (only use in the OfficeServ 100 system) ............3-15 3.17 MISC 3 (4) Card (only use in the OfficeServ 100)..............3-16 3.18 500 MODEM D-Board (common use the OfficeServ 500) .............
  • Page 13 OfficeServ 100 Installation Manual/Ed.00 CHAPTER 6. Connecting Station Equipment Phone ............................6-2 Add-On Module ......................... 6-4 Single Line Telephone ......................6-6 Door Phone and Door Lock Release ..................6-8 ISDN TE (ISDN Phone, G4 FAX, etc) ..................6-11 IP Telephone ..........................6-12 Connecting WBS24 with 4WLI ....................6-13...
  • Page 14 Figure 2.8 Cabling for MDF....................... 2-8 Figure 2.9 Installation of RGU....................2-9 Figure 2.10 Cabling for Battery Connection ................2-11 Figure 3.1 3TRK Card and 6TRK Card ..................3-2 Figure 3.2 6MWSLI Card ......................3-3 © SAMSUNG Electronics Co., Ltd.
  • Page 15 OfficeServ 100 Installation Manual/Ed.00 Figure 3.3 8SLI Card and 2SLI Card ..................3-4 Figure 3.4 8DLI Card and MISC 1/MISC 2 Card ..............3-5 Figure 3.5 TEPRI Card......................3-8 Figure 3.6 PRI Card ......................... 3-8 Figure 3.7 4BRI/2BRI Card ...................... 3-9 Figure 3.8 PLL Card ........................3-10...
  • Page 16 Figure 7.8 PIN Connections for MISC Card to MODEM ............7-10 Figure 7.9 MDF Connections VOICE MAIL to SLI Card............7-11 Figure 10.1 OfficeServ 100 Networking Conceptual Diagram..........10-1 Figure 10.2 Networking Programming Example for Each Point ..........10-15 LIST OF TABLES Table 1.1 Cable Requirements....................1-2...
  • Page 17: Chapter 1. Site Requirements

    This chapter describes site requirements for OfficeServ 100 system installation. 1.1 Site Requirements When planning the installation of the OfficeServ 100, choose a site that meets the following requirements: Select a location for the KSU(Key Service Unit) that has enough space for easy installation and has adequate lighting(See Figure 2.1).
  • Page 18: Specification

    Table 1.3 Dimension and Weights Item Height(mm) Width(mm) Depth(mm) Weight(kg) Basic(Single) Cabinet Expansion(Two) Cabinet 12.5 Door Phone Environmental Limit Table 1.4 Environmental Limit Item Specification Operating Temperature 32-104 °F/0-40 °C Storage Temperature 13.1-158 °F/-10.5-70 °C © SAMSUNG Electronics Co., Ltd.
  • Page 19: System Capacity

    2.1 System Capacity OfficeServ 100 system can have up to 48 stations if SVMi-8 is not used, and can have up to 40 stations if SVMi-8 is used. There is no limit in the analog C.O. line, and ISDN C.O line if any slot is available and PRI(TEPRI) or SVMi-8 can be adopted in the DCS slot on the EXP cabinet of OfficeServ 100.
  • Page 20 Power Supply Unit installed. - 55V Power capacity in consideration of power dissipation OfficeServ 100 new cards. - Support a MAX 48 stations(normal Phones or SLT’s) basically but SVMi-8 or...
  • Page 21: Unpacking And Inspection

    Spare Parts Assembly Before installing OfficeServ 100 Unpack and inspect each card before installing. Check for signs of physical damage. If any damage is detected, do not attempt to install. Contact Samsung Technical Support Department immediately. © SAMSUNG Electronics Co., Ltd.
  • Page 22: Basic Ksu Installation

    Next hang the KSU on the screws and screw it to the back board with the remaining two screws. Tighten all four screws to secure KSU in place.(See Figure 2.1) Mounting Mounting Hole Hole Figure 2.1 Basic KSU (Key Service Unit) © SAMSUNG Electronics Co., Ltd.
  • Page 23: Expansion Ksu Installation

    OfficeServ 100 Installation Manual/Ed.00 2.4 Expansion KSU Installation Expansion KSU is simply attached to basic KSU with the following procedure. This manual instanced the Expansion cabinet A as the installation figures. The installation procedure of Expansion Cabinet A is same with Expansion Cabinet B.
  • Page 24: Figure 2.4 Right Side View Of Basic Ksu

    2) Remove dummy tabs on the right side of the basic with appropriate tools for connection route. A is for MDF cable and B is for signal and power cable.(See Figure 2.4) Figure 2.4 Right Side View of Basic KSU © SAMSUNG Electronics Co., Ltd.
  • Page 25: Figure 2.5 Assemble Between Basic Ksu & Exp.cabinet (1)

    OfficeServ 100 Installation Manual/Ed.00 3) Move Expansion cabinet to basic cabinet and attach it via groove.(See Figure 2.5) Figure 2.5 Assemble between Basic KSU & EXP.Cabinet (1) 4) Fix Expansion cabinet with offered screw to back plane.(See Figure 2.6) Figure 2.6 Assemble Between Basic KSU & EXP.Cabinet (2)
  • Page 26: Figure 2.7 Bottom Side Of Basic Ksu

    7) Connect MDF cable through appropriate path.(See Figure 2.7 & 2.8) MDF Cable Path Figure 2.7 Bottom Side of Basic KSU Figure 2.8 Cabling for MDF 8) Now close the cabinets and switch ON the power. © SAMSUNG Electronics Co., Ltd.
  • Page 27: Rgu Installation

    OfficeServ 100 Installation Manual/Ed.00 2.5 RGU Installation The RGU(Ring Generator Unit) is designed to provide sine-wave ring for Single Line Telephones connected to the various SLT(Single Line Telephone) interface cards(2/8SLI, 6MWSLI) installed in each universal slots in the system. The RGU can be mounted in the Basic KSU by offered screw.
  • Page 28: Grounding

    CHAPTER 2. Installing Basic KSU and Expansion Cabinet 2.6 Grounding A three wire for AC grounding via AC power cord should be used for the OfficeServ 100 system However, if it is suspected that there is a problem with the ground provided at AC outlet or local codes require a solid earth ground to be connected to the KSU, the existing third wire ground must be disconnected before power is applied.
  • Page 29: Battery For Power Failure

    If you want to use OfficeServ 100 system during power failure, install appropriate batteries. If you adopt battery whose capacity is too large, OfficeServ 100 system may be shut down, and if too small, OfficeServ 100 system may not operate during power failure. In any case, use battery connection cable offered with OfficeServ 100.
  • Page 30: Recommended Battery Specification

    Max KTS current consumption: 30 mA When installing appropriate batteries Be sure the polarity is observed. Equipment damage will result if polarity is reversed. Do not connect external AC/DC power to the OfficeServ 100 system if the system is damaged by electrical power. 2-12...
  • Page 31: Chapter 3. Installing Printed Circuit Cards

    OfficeServ 100 Installation Manual CHAPTER 3. Installing Printed Circuit Cards This chapter describes how to install each card of OfficeServ 100 system. © SAMSUNG Electronics Co., Ltd.
  • Page 32: 3Trk Card

    This card has no selectable option. Insert the 3 TRK card into the appropriate slot. Push firmly in the middle of both card ejectors to ensure that it is fully inserted into the back plane connector. Figure 3.1 3TRK Card and 6TRK Card © SAMSUNG Electronics Co., Ltd.
  • Page 33: Trk Card

    OfficeServ 100 Installation Manual/Ed.00 3.2 6 TRK Card 6 loop start trunk ports and 2 PFT ports for PFT.(See Figure 3.1) This card has no selectable option. Insert the 6 TRK card into the appropriate slot. Push firmly in the middle of both card ejectors to ensure that it is fully inserted into the back plane connector.
  • Page 34: Sli Card

    This card has no selectable option. Insert the 8 DLI card into the appropriate slot. Push firmly in the middle of both card ejectors to ensure that it is fully inserted into the back plane connector. © SAMSUNG Electronics Co., Ltd.
  • Page 35: Misc 1 Card (Only Use In The Idcs 100 Or Dcs Compact-Ii System)

    OfficeServ 100 Installation Manual/Ed.00 3.7 MISC 1 Card (only use in the iDCS 100 or DCS Compact-II system) Which has many miscellaneous function DTMF receiver(4ch), RS232C, BGM, PAGE, COMMON PURPOSE RELAY(3port)(See Figure 3.4). Select appropriate type of MISC card for your system. If you choose MISC 1 card then insert the MISC 1 card into the MISC slot and push firmly in the middle of both card ejectors to ensure that it is fully inserted into the back plane connector.
  • Page 36: Misc 2 Card (Only Use In The Idcs 100 Or Dcs Compact-Ii System)

    - MISC 1(2) cards only used together with the MEM4(or MEM3 or MEM2: iDCS 100 or DCS Compact II SYSTEM) cards - New MISC 1A(2A) Card installed with 500 MODEM is not operation SIO 1 RS232C. © SAMSUNG Electronics Co., Ltd.
  • Page 37: Tepri Or Pri Card

    OfficeServ 100 Installation Manual/Ed.00 3.9 TEPRI or PRI Card The PRI card supports 30 channel ISDN PRI interface ports. This card has no selectable options. Insert PRI into the last slot in the Expansion cabinet(type A or B). Firmly push in the middle of the card to ensure that it is fully inserted into the back plane connector.
  • Page 38: Figure 3.5 Tepri Card

    Status LED Name Function Normal Status Error Status MODE LED’s TP1 & TP2 show the span type E1 mode E1 PRI mode T1 mode T1 PRI mode Figure 3.5 TEPRI Card Figure 3.6 PRI Card © SAMSUNG Electronics Co., Ltd.
  • Page 39: 4Bri (4S0T0)/2Bri (2S0T0) Card

    OfficeServ 100 Installation Manual/Ed.00 3.10 4BRI (4S0T0)/2BRI (2S0T0) Card This card supports both of S and T reference points defined by ITU-T. You can select the S/T mode of each port respectively by MMC. Insert the 4BRI(4S0T0) card or 2BRI(2S0T0) into the universal slot and push firmly in the middle of both card ejectors to ensure that it is fully inserted into the back plane connector.
  • Page 40: Pll Card

    This card has no selectable option and this card is only used when TEPRI, PRI or BRI card is adopted. Push firmly in the middle of 14 pin female connector. Figure 3.8 PLL Card 3-10 © SAMSUNG Electronics Co., Ltd.
  • Page 41: Mem Card (Mem3 Or Mem4): Only Use In The Idcs 100 System

    OfficeServ 100 Installation Manual/Ed.00 3.12 MEM Card (MEM3 or MEM4): only use in the iDCS 100 system Select the appropriate of MEM for the system. Make sure that back up switch is OFF position. Insert the MEM card in the KSU slot labeled MEM. Push in middle of the MEM card(MEM3 or MEM4) to ensure that it is fully inserted into the back plane connector.
  • Page 42: Svmi-4 Card

    3.13 SVMi-4 Card The SVMi-4 is a self contained plug in card supporting voice mail and auto attendant for the OfficeServ 100. It is designed to meet the demands of the sophisticated voice mail user without sacrificing simplicity. The SVMi-4 may act as an Auto Attendant system only, a Voice mail system only or both.
  • Page 43: Svmi-8 Card

    The SVMi-8 card is installed in DCS slot on the expansion cabinet. Only one SVMi-8 can be installed in an OfficeServ 100 system and it counts as eight stations of the power supply rating. Check that the cabinet power switch is in the OFF position. Next, position the SVMi-8 card in the grooves of the card guide and gently slide the card in until it makes contact with the connector.
  • Page 44: Itm3 Card (Only Use In The Idcs 100 System)

    This LED indicates a processing state for voice packeting in Call. This LED is ON when call service is ready. This LED is flicker at a low rate to indicate O.S task in Software running. Figure 3.13 ITM3 Card 3-14 © SAMSUNG Electronics Co., Ltd.
  • Page 45: Mcp1 Card (Only Use In The Officeserv 100 System)

    OfficeServ1500 system. MCP1 card is mounted on the MEM slot of the OfficeServ 100 basic cabinet. Push in middle of the MCP1 card to ensure that it is fully inserted into the back plane connector.
  • Page 46: Misc 3 (4) Card (Only Use In The Officeserv 100)

    CHAPTER 3. Installing Printed Circuit Cards 3.17 MISC 3 (4) Card (only use in the OfficeServ 100) Many miscellaneous function DTMF receiver(4ch), BGM, PAGE, Common Purpose Relay(3port), CID Rx, 500 MODEM(option) are MISC 1. MISC 4 support MISC 3 feature and 4 Channel AA.
  • Page 47: Modem D-Board (Common Use The Officeserv 500)

    3.18 500 MODEM D-Board (common use the OfficeServ 500) This board has no selectable options and installs on the MISC3(4) board for OfficeServ 100 or MISC 1A(2A) for iDCS 100 or DCS Compact-II system. The MODEM board provides a 56Kbps/V90 modem for communicating with the system remotely.
  • Page 48: Mgi3 Card (Only Use In The Officeserv 100)

    CHAPTER 3. Installing Printed Circuit Cards 3.19 MGI3 Card (only use in the OfficeServ 100) The MGI3 card supports the VoIP Gateway, which enables telephone calls through the Internet. Since the MGI3 card cannot support the H.323 protocol by itself, the MGI3 card shall always be used together with the MCP1 card.
  • Page 49: Figure 3.17 Led Display Of The Mgi3 Card

    OfficeServ 100 Installation Manual/Ed.00 Color Description Light Green Displays if RTP data is incoming through LAN. - Blink: RTP data is received normally. - Off: No RTP data is being received. Figure 3.17 LED Display of the MGI3 Card Figure 3.18 MGI3 Card ©...
  • Page 50: 4Wli Card (Only Use In The Officeserv 100)

    CHAPTER 3. Installing Printed Circuit Cards 3.20 4WLI Card (only use in the OfficeServ 100) The 4WLI card provides wireless solution to the OfficeServ 100 system, and provides cable interface between the system and COMBO type WLAN Base Station(WBS24), which is the access point for WLAN.
  • Page 51: Chapter 4. Power Up Procedures

    OfficeServ 100 Installation Manual CHAPTER 4. Power Up Procedures This chapter describes power up procedures of OfficeServ 100 system. 4.1 Connect Power to The System During the initial installation, it is best to verify proper system operation before plugging in any Amphenol-type cable to the MDF.
  • Page 52: Mcp1 (Mem) Card Indications

    LAN Transmit/Receive data speed is 100 Mbps LAN Data Rx(Receive) Status indicates that there is no received data from the LAN connection indicates that the link from the LAN interface is being set up Flicker indicates a message has been received. © SAMSUNG Electronics Co., Ltd.
  • Page 53: Card Verification

    OfficeServ 100 Installation Manual/Ed.00 MP(XRC855T in the MCP1 Board) Processor Status: MP Run LED indicates that Power is OFF indicates that the MP is booting Flicker indicates normal operation. SP(68EC000 in the 008 Base Board) C#2) Processor Status: SP Run LED indicates that Power is OFF indicates that the SP is booting Flicker indicates normal operation.
  • Page 54 CHAPTER 4. Power Up Procedures This page is intentionally left blank. © SAMSUNG Electronics Co., Ltd.
  • Page 55 OfficeServ 100 Installation Manual CHAPTER 5. Connecting Trunk Line Circuit This chapter describes how to connect CO circuit. When installing or modifying telephone lines. To limit the risk of personal injury, always follow these precautions before connecting CO circuit. - Never install telephone wiring during a lightning storm.
  • Page 56: Chapter 5. Connecting Trunk Line Circuit

    CHAPTER 5. Connecting Trunk Line Circuit 5.1 Loop Start Lines The OfficeServ 100 system requires MDF connection. All CO Line and Station is connected to the system with MDF.(See Figure 5.1) 25 PAIR CABLE WITH FEMALE CONNECTOR TO BASIC P2 25 PAIR CABLE WITH FEMALE CONNECTOR TO EXPANSION P5 SLOT NO.
  • Page 57: Ops (Off Premised Station)

    OfficeServ 100 Installation Manual/Ed.00 5.2 OPS (Off Premised Station) Using one pair twisted #24 AWG or #26 AWG wire, cross-connect each any 2SLI port to telephone company OPS circuits.(See Figure 5.2) 25 PAIR CABLE WITH FEMALE CONNECTOR TO BASIC P1...
  • Page 58: Isdn Co Lines

    CHAPTER 5. Connecting Trunk Line Circuit 5.3 ISDN CO Lines OfficeServ 100 system is fully ISDN compatible. For Basic Rate Interface BRI card can be used as ISDN TE(Terminal Equipment) or NT2(Network Termination 2/Multiway ISDN Interface). When programmed to T-mode(default setting) this port provides T point and can be access NT(NT1 or NT2) derived from CO Line Connect each point of BRI card to NT to use as ISDN TRK.
  • Page 59: Figure 5.4 Mdf Connections For Isdn Co Line To Card (4Bri)

    OfficeServ 100 Installation Manual/Ed.00 If S-interface is needed, ISDN C.O line from C.O must be connected to MDF. 25 PAIR CABLE WITH FEMALE CONNECTOR TO BASIC P2 25 PAIR CABLE WITH FEMALE CONNECTOR TO EXPANSION P5 SLOT NO. PIN NO.
  • Page 60: Figure 5.5 Mdf Connections For Isdn Co Line To Card (2Bri)

    Figure 5.5 MDF Connections for ISDN CO Line to Card (2BRI) 4BRI(including 2BRI) card can support both of S and T reference points defined by ITU-T. Detailed description & MMC is referred in Programming Manual. © SAMSUNG Electronics Co., Ltd.
  • Page 61: Figure 5.6 Tepri (Pri) Connection For Reference Only

    OfficeServ 100 Installation Manual/Ed.00 RJ-45 connector to TEPRI(PRI) card RJ-45 NAME DESCRIPTION RECEIVE TWISTED PAIR NOT USED TRNSMIT TWISTED PAIR NOT USED NOT USED NOT USED ISDN C.O CIRCUIT Figure 5.6 TEPRI (PRI) Connection for Reference Only When installing TEPRI(PRI) Card TEPRI(PRI) card must be installed to DCS slot in Expansion Cabinet only.
  • Page 62 CHAPTER 5. Connecting Trunk Line Circuit This page is intentionally left blank. © SAMSUNG Electronics Co., Ltd.
  • Page 63 OfficeServ 100 Installation Manual CHAPTER 6. Connecting Station Equipment This chapter describes how to connect station equipments to the OfficeServ 100 system. When installing or modifying telephone lines. To limit the risk of personal injury, always follow these precautions before connecting CO circuit.
  • Page 64: Chapter 6. Connecting Station Equipment

    Yellow/grey DLI RING Brown/yellow DLI TIP Yellow/brown DLI RING Green/yellow DLI TIP Yellow/green DLI RING CONNECT TO ANY DLI CIRCUIT ON KSU P1. DIGITAL PHONE Figure 6.1 MDF Connections Digital Phone to Basic KSU P1 © SAMSUNG Electronics Co., Ltd.
  • Page 65: Figure 6.2 Mdf Connections Digital Phone To Option Card

    Figure 6.2 MDF Connections Digital Phone to Option Card When connecting a 12 button phone to a DLI port Because the OfficeServ 100 is a self-configuring system, if you connect a 12 button phone to a DLI port that previously had a 24 button phone installed, the existing data will be rewritten with 12 button phone default data(See MMC 723).
  • Page 66: Add-On Module

    DLI TIP Yellow/grey DLI RING Brown/yellow DLI TIP Yellow/brown DLI RING Green/yellow DLI TIP Yellow/green DLI RING CONNECT TO ANY DLI CIRCUIT ON KSU P1. ADD-ON MODULE Figure 6.3 MDF Connections AOM to Basic KSU P1 © SAMSUNG Electronics Co., Ltd.
  • Page 67: Figure 6.4 Mdf Connections Aom To Option Card

    OfficeServ 100 Installation Manual/Ed.00 25 PAIR CABLE WITH FEMALE CONNECTOR TO BASIC P2 25 PAIR CABLE WITH FEMALE CONNECTOR TO EXPANSION P5 SLOT NO. PIN NO. 8 DLI 25, 50 STN 1 SLOT NO. PIN NO. 8 DLI 24, 49...
  • Page 68: Single Line Telephone

    ONE PAIR TWISTED Black/grey SLI RING SHEATHED STATION CABLE 24 OR 26 AWG CONNECT TO ANY DLI CIRCUIT ON A EXP CARD SINGLE LINE TELEPHONE Figure 6.5 MDF Connections Single Line Telephone to 2 SLI Card © SAMSUNG Electronics Co., Ltd.
  • Page 69: Figure 6.6 Mdf Connections Slt To Option Card

    OfficeServ 100 Installation Manual/Ed.00 25 PAIR CABLE WITH FEMALE CONNECTOR TO BASIC P2 25 PAIR CABLE WITH FEMALE CONNECTOR TO EXPANSION P5 SLOT NO. PIN NO. 8 SLI 6 MWSLI 25, 50 SLT 1 SLT 1 SLOT NO. PIN NO.
  • Page 70: Door Phone And Door Lock Release

    DOOR PHONE Green/yellow DLI TIP INTERFACE Yellow/green DLI RING THREE PAIR MODULE(DPIM) MODULAR CABLE CONNECT TO ANY DLI CIRCUIT DOOR PHONE TWO PAIR MODULAR CABLE Figure 6.7 MDF Connections Door Phone to Basic KSU P1 © SAMSUNG Electronics Co., Ltd.
  • Page 71: Figure 6.8 Mdf Connections Door Phone To Door Card

    OfficeServ 100 Installation Manual/Ed.00 25 PAIR CABLE WITH FEMALE CONNECTOR TO BASIC P2 25 PAIR CABLE WITH FEMALE CONNECTOR TO EXPANSION P5 SLOT NO. PIN NO. 8 DLI 25, 50 STN 1 SLOT NO. PIN NO. 8 DLI 24, 49...
  • Page 72 The contacts are rated at 24 VDC-1 amp. Commercial AC Power Do not attempt to connect commercial AC power to the contacts on the DPIM. 6-10 © SAMSUNG Electronics Co., Ltd.
  • Page 73: Isdn Te (Isdn Phone, G4 Fax, Etc)

    Figure 6.9 MDF Connections ISDN TEs to 2BRI/4BRI Card 4BRI(including BRI)mode must be programmed by MMC OfficeServ 100 is a self-configuring system, but you must program 4BRI (including 2BRI) mode by MMC #423, #419, #421, #418, #424. © SAMSUNG Electronics Co., Ltd.
  • Page 74: Ip Telephone

    Therefore, to use an IP phone, prepare the IP Telephone, MGI3 card, and connect MCP1 card to the Ethernet port. Refer to the programming manual for appropriate settings before use. OfficeServ 100 LAN Network MCP1 Ethernet MGI3 Ethernet IP Phone Digital Phone Figure 6.10 IP Telephone Connection Diagram 6-12 © SAMSUNG Electronics Co., Ltd.
  • Page 75: Connecting Wbs24 With 4Wli

    WBS24: COMBO type WLAN Base Station WIP5000M: WIP Wireless terminal Before mounting the 4WLI card to the system, note that the OfficeServ 100 system shall be configured in the Premium configuration and that only one card shall be installed per system.
  • Page 76: Figure 6.11 Wbs24-4Wli Wiring Diagram

    6, 31 4, 5 D Channel data 5, 30 SLOT3 3, 6 Sync line 4, 29 4, 5 D Channel data 3, 28 SLOT3 3, 6 Sync line 2, 27 Figure 6.11 WBS24-4WLI Wiring Diagram 6-14 © SAMSUNG Electronics Co., Ltd.
  • Page 77: Music On Hold/Back Ground Music

    CHAPTER 7. Connecting Optional Equipment This chapter describes how to connect optional equipments to the OfficeServ 100 system. 7.1 Music On Hold/Back Ground Music Connect each customer-provided music source to the music input on the KSU connecting block(See Figure 7.1).
  • Page 78 Each C.O. Line(trunk) can be programmed to receive a music source, system generated TONE or NO MUSIC when it is put on hold. See MMC 408. Each phone can receive a music source or NO MUSIC for background music. See programming manual for instructions(See MMC 308). © SAMSUNG Electronics Co., Ltd.
  • Page 79: External Paging

    OfficeServ 100 Installation Manual/Ed.00 7.2 External Paging The KSU provides a voice pair to be used with customer-provided paging equipment. Connect the customer provided paging equipment to the page output pins of the KSU connecting block(See Figure 7.2). The page voice pair is 600 ohm impedance. When the amplifier page input is not 600 ohm, an impedance matching transformer must be used.
  • Page 80: Figure 7.3 Mdf Connections Connecting Page Amplifier To Ksu

    NOTE: THE TACT RELAYS REQUIRE A MISC CARD Figure 7.3 MDF Connections Connecting Page Amplifier to KSU Commercial AC Power Do not attempt to connect commercial AC power to the contacts on the External Paging. © SAMSUNG Electronics Co., Ltd.
  • Page 81: Common Bell

    OfficeServ 100 Installation Manual/Ed.00 7.3 Common Bell A customer-provided loud ringing device can be controlled using the dry contact pair on the KSU.(See Figure 7.4). 25 PAIR CABLE WITH FEMALE CONNECTOR TO KSU P1 COLOR CIRCUIT FUNCTION Blue/black OPEN A...
  • Page 82: Ring Over Page

    Program the line or lines to ring a hunt group. Using MMC 601, assign ROP as a destination in this hunt group. Ring over page can be used for day or night operation or both. © SAMSUNG Electronics Co., Ltd.
  • Page 83: Smdr (Station Message Detail Recording)

    Use MMC 725 to set SMDR print options and MMC 804 to set the transmission parameters and the MISC port. Use MCP1: OfficeServ 100 System To receive SMDR printout, traffic or alarm reports connect a customer-provided printer or PC to one of the RS232C DB9 connectors or by LAN interface on the MCP1 card.
  • Page 84: Pc Programming

    MISC end and then attach one that matches the requirements of the PC to the other end. This cable must not exceed 300 feet. Use MMC 804 to set the transmission parameters and the MISC port. © SAMSUNG Electronics Co., Ltd.
  • Page 85 LAN port requires a data cross over cable if connecting directly to the LAN port or a standard data cable if connecting via a LAN. In both cases the OfficeServ 100 IP address and PC IP address(PCMMC ADDRESS) must be programmed in MMC 830.
  • Page 86: Remote Programming

    Use MMC 804 to set the transmission parameters and the MISC port to be used. Use MCP1 or OfficeServ 100 System The OfficeServ 100 can be remote programmed with a PC equipped connected to the MCP1 LAN port or via serial interface of the MCP1.
  • Page 87: Voice Mail/Auto Attendant

    OfficeServ 100 Installation Manual/Ed.00 7.9 Voice Mail/Auto Attendant System operation provides special programming and hardware for use with a customer- provided voice mail/auto attendant system. Both single line stations on the 2 SLI card provide a disconnect signal required for VM/AA operation. Use one pair twisted #24 AWG...
  • Page 88 CHAPTER 7. Connecting Optional Equipment This page is intentionally left blank. 7-12 © SAMSUNG Electronics Co., Ltd.
  • Page 89: Chapter 8. Installing Kdb (Keyset Daughter Board)

    OfficeServ 100 Installation Manual CHAPTER 8. Installing KDB (Keyset Daughter Board) This chapter describes how to install the KDB(Keyset daughter Board) to the phone. 8.1 iDCS FKDBD (KDB-Digital Line Interface) This is a daughter board that can be installed only in the 18 or 28 button phone.
  • Page 90: Idcs Fkdbf (Kdb-Full Duplex)

    The second method is to use a multi-pair station cable, connecting separate station jacks to the first two pairs. A line cord can now be connected between the daughter board and the second jack. This returns the daughter board port to the MDF for cross-connection to another cable run. © SAMSUNG Electronics Co., Ltd.
  • Page 91: Chapter 9. Changing Software

    4) Remove the new EPROM from their protective packaging and confirm that the legs on the EPROMs are straight. If the legs are not straight, contact Samsung Technical Support. Carefully insert the new EPROM in their designated sockets.
  • Page 92: Mem4

    Please refer to the PCMMC Technical Manual to perform a software upgrade for a MEM4 card. 9.3 MCP1 When software change is required, it must be done via PCMMC through the LAN interface. Please refer to the PCMMC Technical Manual to perform a software upgrade for a MCP1 card. © SAMSUNG Electronics Co., Ltd.
  • Page 93: Chapter 10. Networking Description And Programming Procedure

    Digital phone Digital phone Figure 10.1 OfficeServ 100 Networking Conceptual Diagram The networking function of OfficeServ 100 system uses Q-SIG(Q Signaling), and is classified into(TE)PRI Networking and VoIP Networking depending on the connection method between each system. OfficeServ 100 system using Q-SIG provides the functions below.
  • Page 94: Provide Q-Sig Basic Function

    CHAPTER 10. Networking Description and Programming Procedure 10.1.1 Provide Q-SIG Basic Function Networking of the OfficeServ 100 system provides basic Q-SIG functions as follows: 10.1.1.1 Intercom Call This function allows you to call a station of another system as if calling the station in the same system.
  • Page 95: Provide Q-Sig Additional Function

    10.1.3 Provide Q-SIG Additional Function Networking of the OfficeServ 100 system provides Q-SIG additional functions as follows: 10.1.3.1 Call Transfer and Transfer Recall by Join This function enables you to transfer the busy call to a station of another system as if transferring calls within a same system.
  • Page 96: Call Offer

    10.1.3.12 Centralized Voice Mail This function enables you to install only one voice mail in the network. You shall use the dedicated voice mail(SVMi-4/8) of the subscriber card type to use this function. 10-4 © SAMSUNG Electronics Co., Ltd.
  • Page 97: Programming Methods

    For PRI networking, TEPRI card shall be specified for networking. If the OfficeServ 100 systems are connected by using TEPRI not trunk line, the one switch within the card is set to the ‘NT’ mode and the other switch is set to ‘TE’ mode. System- based clock shall be defined in Program 828.
  • Page 98: Unify Phone Number System

    When a call is connected to networking trunk line, the OfficeServ 100 system identifies the incoming number as a node number & a phone number and processes it.
  • Page 99 OfficeServ 100 Installation Manual/Ed.00 Program 824. Convert Auto Route Selection Expansion Dial The networking dial number is entered in Program 724 for this program. If index 01 from the networking dial number of Program 724 is set to ‘22,’ ⓐ will be displayed.
  • Page 100: Route Incoming And Outgoing

    ‘N’ is selected. PRI Mode: If ‘DDI’ is specified, the call is connected according to Program 714. The networking functions of the OfficeServ 100 system are based on ‘DDI’ mode. Therefore, the functions shall be always used in ‘DDI’ mode.
  • Page 101 OfficeServ 100 Installation Manual/Ed.00 DELETE: The number of digits deleted from the forepart of the received number that is sent through the trunk line when the recipient is trunk line, trunk line group, auto route selection use code, or the networking dial number.
  • Page 102 I: Inserts digit used to add digits in front of the dialed number. A: Appends digit used to add digits in the rear part of the dialed number. 10-10 © SAMSUNG Electronics Co., Ltd.
  • Page 103: Items Required For Additional Feature

    Program 823. The default value is recommended since there are cases when the name and number is always sent to the recipient according to the CONP level, not according to these options because the OfficeServ 100 networking was supposed for connections between iDCS systems.(Default value is set to always send the name and number)
  • Page 104: Call Forwarding

    Program 823 shall be set to ‘Y’. To forward a call to a station of another system when the call is not answered during the set time, the ‘CFNR’ option in Program 823 shall be set to ‘Y’. 10-12 © SAMSUNG Electronics Co., Ltd.
  • Page 105: Call Completion

    OfficeServ 100 Installation Manual/Ed.00 Call Offer In case the counter party is busy or not answering when the station of another system is called, the Camp-On function is required just like a calling in the same system. The ‘Call Offer’ option in Program 823 shall be set to ‘Y’.
  • Page 106 In order to remove this added node number when sending the caller ID to the voice mail, the ‘Remote CID Number’ option of Program 825 shall be set to ‘Yes’. 10-14 © SAMSUNG Electronics Co., Ltd.
  • Page 107: Programming Example

    OfficeServ 100 Installation Manual/Ed.00 10.3 Programming Example Figure 10.2 below shows the example of the networking programming that uses both of the PRI networking and the VoIP networking, and is configured only with OfficeServ 100 systems. System A System B...
  • Page 108: System A Programming

    The station call of the system C 09325 09426 The station call of the system D 09251 The station group call of the system B 09352 The station group call of the system C 10-16 © SAMSUNG Electronics Co., Ltd.
  • Page 109 OfficeServ 100 Installation Manual/Ed.00 Index Phone No. Converted No. DISP 09453 The station group call of the system D Program 714 Enter the Conversion Table of Dialing a Station Directly (MCP1) Entry Digit Delete Name 2100~2699 are applicable. 2*** 5*** Calls Attendant and Voice mail.
  • Page 110: System B Programming

    Program 820 Set System Link Number (MCP1) Index Link ID Signal G/W SELF 168.219.110.110 SYS01 168.219.100.100 SYS02 SYS03 168.219.120.120 Program 821 Set Networking trunk line Set TEPRI card connected with System A as Q-Signaling. 10-18 © SAMSUNG Electronics Co., Ltd.
  • Page 111 OfficeServ 100 Installation Manual/Ed.00 Program 724 Change Dial Numbers (MCP1) STN Dial Number Set the extension number as 2100~2399. STNG Dial Number Set the extension group number as 5100~5179. TRKG Dial Number Set 800 and 803. FEAT Dial Number Set LCR as 9 To make trunk line call, dial 9 and the target telephone number.
  • Page 112 Local call: Sends to the system A. 0015 0016 0017 0018 0019 0020 0021 Program 712 Enter the Route Table for Auto Route Selection (MCP1) Table Time Class Route Modify Sends to the system A for outgoing through trunk line 10-20 © SAMSUNG Electronics Co., Ltd.
  • Page 113: System C Programming

    OfficeServ 100 Installation Manual/Ed.00 Program 713 Enter a Dial Conversion Table for Auto Route Selection (MCP1) Table Delete Insert Append 0919 The first digit(9)-added number is sent to the system A for outgoing through trunk line Program 825 ADD Number To Name...
  • Page 114 The station call of the system B: Sends to the system A 0012 The station call of the system D: Sends to the system A 0013 Special call: Sends to the system A 0014 Local call: Sends to the system A 10-22 © SAMSUNG Electronics Co., Ltd.
  • Page 115 OfficeServ 100 Installation Manual/Ed.00 Index Digit Length LCRT 0015 0016 0017 0018 0019 0020 0021 Program 712 Enter the Route Table for Auto Route Selection (MCP1) Table Time Class Route Modify Sends to the system A for outgoing through trunk...
  • Page 116: System D Programming

    IDX-04: 23 IDX-05: 24 IDX-06: 25 IDX-07: 50 IDX-08: 51 IDX-09: 52 Program 824 Convert Auto Route Selection Expansion Dial Index Phone No. Converted No. DISP 09120 09221 09222 09223 09324 09325 09150 09251 09352 10-24 © SAMSUNG Electronics Co., Ltd.
  • Page 117 OfficeServ 100 Installation Manual/Ed.00 Program 714 Enter the Conversion Table of Dialing a Station Directly (MCP1) Entry Digit Delete Name 2*** 5*** Program 603 trunk line Group (MCP1) 803 Set VoIP Networking Signaling trunk line Program 710 Enter a Digit for Auto Route Selection (MCP1)
  • Page 118 Table Delete Insert Append 0919 The first digit(9)-added number is sent to the system A for outgoing through trunk line Program 825 ADD Number To Name Use Remote Voice Mail Remote VM Number 5049 10-26 © SAMSUNG Electronics Co., Ltd.
  • Page 119: Annex A. Abbreviation

    OfficeServ 100 Installation Manual ANNEX A. Abbreviation Alternating Current Add On Module Access Point Basic Rate Interface CCBS Call Completion to Busy Subscriber CCNR Cell Completion on No Reply Call Forwarding Busy CFNR Call Forwarding No Reply Call Forwarding Unconditional...
  • Page 120 Keyset Daughter Board Key Service Unit Local Area Network Liquid Crystal Display Light Emitting Diode Main Control Processor Main Distribution Frame Media Gateway Interface MISC Miscellaneous Man Machine Communication MWSLI Message Waiting Single Line Interface Network Termination © SAMSUNG Electronics Co., Ltd.
  • Page 121 OfficeServ 100 Installation Manual/Ed.00 Off Premised Station Off Premises extension Printed Circuit Board Pulse Code Modulation PCMMC PC based Man Machine Communication Power Failure Transfer Phase Locking Loop Primary Rate Interface Power Supply Unit QDASL Quad Digital Adaptor Subscriber Loops...
  • Page 122 ANNEX A. Abbreviation Wide Area Network Wireless Base Station Wireless IP Phone © SAMSUNG Electronics Co., Ltd.
  • Page 123 OfficeServ 100 Installation Manual ©2004 Samsung Electronics Co., Ltd. All rights reserved. Information in this document is proprietary to SAMSUNG Electronics Co., Ltd. No information contained here may be copied, translated, transcribed or duplicated by any form without the prior written consent of SAMSUNG.