Siemens SINAMICS G150 Operating Manual page 128

Converter cabinet units 75 kw to 800 kw
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

Output Terminals
List of Signals for the Analog Outputs
Signal
Speed setpoint upstream of setpoint filter
Motor speed unsmoothed
Actual speed after smoothing
Output frequency
Output current
DC link voltage
Torque setpoint
Output power
For diagnostic purposes
Control deviation
Slip frequency
Actual phase current
Control factor
Field-producing current setpoint
Field-producing actual current
Torque-producing current setpoint
Torque-producing actual current
Flux setpoint
Actual flux
DC link voltage setpoint
Phase voltage
For further diagnostic purposes
Speed controller output
I component of speed controller
8-4
Parameter
Unit
r0060
1/min
r0061
1/min
r0063
1/min
r0066
Hz
r0068
Aeff
r0070
V
r0079
Nm
r0082
kW
r0064
1/min
r0065
Hz
r0069
A
r0074
%
r0075
A
r0076
A
r0077
A
r0078
A
r0083
%
r0084
%
r0088
V
r0089
V
r1480
Nm
r1482
Nm
11/03
Scaling
(100 % = ...) (see
Table 8-1)
p2000
p2000
p2000
Reference frequency
p2002
p2001
p2003
r2004
p2000
Reference frequency
p2002
Reference control factor
p2002
p2002
p2002
p2002
Reference flux
Reference flux
p2001
p2001
p2003
p2003
SINAMICS G150
Operating Manual

Advertisement

Table of Contents
loading

Table of Contents