Adjusting The Angle Of The Operation Unit - Konica Minolta 7145 Service Manual

Hide thumbs Also See for 7145:
Table of Contents

Advertisement

SCANNER SECTION
3.2
Adjusting the Angle of the
Operation Unit
A. Procedure
1. Remove the 2 screws [1].
2. Remove the operating section stopper [2].
3. Remove the 2 screws [3] for each position. And
then install the angle adjustment member [4] in
the specified position.
The angle adjustment member corresponds to 7
degrees for the right position and to 15 degrees
for the left position. However, this is not used for
the setting of 33 degrees.
4. Change the installation direction of the operat-
ing section stopper [2] and set it at the position
for 7 or 15 degrees. However, this is not used
for the setting of 33 degrees.
Note:
• The angle of the operation unit can be adjusted at
the following 3 stages: However, the setting at 33
degrees is available only when combined with the
paper exit tray.
5. Install the operating section stopper [2].
6. Fasten the operation unit [5] with the 2 screws
[1].
[1]
[1]
3-10
[3]
[4]
[5]
[4]
[3]
[2]

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

722272357228

Table of Contents