Radf Original Size Detection; Bypass Size Detection Adjustment; Action For Mounting When Reinstalling The Hdd - Konica Minolta 7145 Service Manual

Hide thumbs Also See for 7145:
Table of Contents

Advertisement

9.2

RADF Original Size Detection

This adjustment is done when RADF fails to cor-
rectly detect size of an original.
A. Procedure
1. Enter the 47 mode.
2. "47 mode menu screen"
Press "69" by means of the numeric keys.
Check that "069-000" appears in the message
display area.
3. Set the original guide plate to the minimum size
(width) position, then press the [START] key.
4. To end the output check, press the [STOP] key.
5. Press the
button.
6. Enter "1" from the the numeric keys.
Make sure that "069-001" is indicated in the
message display area.
7. Set the original guide plate to the maximum size
(width) position, then press the [START] key.
8. To end the output check, press the [STOP] key.
9. To end the 47 mode, turn the SW2 OFF.
9.3
Bypass Size Detection
Adjustment
Perform this adjustment if paper size detection at
the bypass feed tray does not function correctly.
A. Procedure
1. Enter the 47 mode.
2. "47 mode menu screen"
Press "28" by means of the numeric keys.
Check that "028-000" appears in the message
display area.
3. Set a sheet of A4R paper in the bypass tray.
4. Press the
button.
5. Press [1] by means of the numeric keys.
Check that "028-001" appears in the message
display area.
6. Press the [START] key.
7. Press the [STOP] key.
8. Set a sheet of A4 paper in the bypass tray.
9. Press the
button.
10. Press "2" by means of the numeric keys.
Check that "028-002" appears in the message
display area.
11. Press the [START] key.
12. To end the output check, press the [STOP] key.
13. Set a sheet of B6R paper in the Bypass tray.
14. Press the button.
15. Press [3] by means of the numeric keys.
Check that "028-003" appears in the message
display area.
16. Press the [START] key.
17. Press the [STOP] key.
18. To end the 47 mode, turn the SW2 OFF.
9.4
Action for Mounting When
Reinstalling the HDD
Removing the HDD for analysis of an abnormality
and then reinstalling it after turning on and off the
power may result in no recognition of the HDD. To
avoid a condition like this, conduct this setting.
A. Procedure
1. Enter the 47 mode.
2. "47 mode setting screen"
Press the No. of sheets setting button to enter
"15". Check to see if "015-000" is displayed in
the message display column.
3. Press the
button.
4. Press the No. of sheets setting button to enter
"97".
Check to see if "015-097" is displayed in the
message display column.
5. Press the [START] key.
6. Press the [STOP] key to terminate the setting.
7. To end the 47 mode, turn the SW2 OFF.
Note:
• When the data is in nonconformity, an error may
occur. In that case, execute the format (key oper-
ator mode).
1-77
47 MODE
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

722272357228

Table of Contents