1.2.5
AE control
During AE scan, the CCD sensor provided on the ADB (A/D conversion board) reads the density level of
the original. The CPU on the SCB (System control board) process the data and, based on the results,
selects the γ correction curve that will best reproduce the original.
A. AE sampling range
(1) While in platen copying
Main scanning direction
•
Based on the original size recognized in the APS or out-of-original erasure mode, the range excepting
10mm in front and in rear.
Sub-scanning direction
•
The range of 30mm from the leading edge of the original. However, the range excepting L/100mm in
left and right when the length of the original is L mm.
[1]
Original
[2]
Leading edge of original
[3]
10 mm
[2]
10 mm
L
L
mm
mm
100
100
30 mm
L mm
[3]
AE sampling range
2-7
SCANNER SECTION
[1]